KRONHE MARSHALL vortex flowmeters operate on the Karman
vortex street principle to measure volumetric flow rate of gases /steam
and liquids. VFM 1091 computes normalized volumetric and mass flow
rates from operating & normalized density values supplied through
operator interface.

Items included with shipment for Compact flowmeter

Compact Vortex flowmeter and operating instructions

Installation and Operating Instructions

Mounting bolts, washers, nuts

Programming chart indicating factory configuration setting

Optional upstream and downstream pipes

Gaskets between primary head & pipeline

Items included with shipment for field mounted
Flowmeter

Field mounted sensor VFS 1091 F

Pipe/Wall mounted separated signal converter VFC 091F

Connecting Cable (10m) between VFS 1091 F & VFC 091F

Installation and Operating Instructions

Mounting bolts, washers, nuts

Programming chart indicating factory setting.

Provided by customer

All cables for electrical connections.

1. Flow direction and meter position -

Flow must always be in the direction of the arrow, bluff side of

vortex-shedding body facing incoming flow i.e. upstream side.

Vertical pipe run: upward flow direction

Horizontal pipe run: see below

2. Difference between inside diameters of primary head and

pipeline

D

Ν

Meter size of primary head in millimeters or Inches

Φ

Inside diameter of primary head in millimeters Max.

∆Φ

allowable difference between inside
diameters of primary head and pipeline

Ensure that the bore of upstream and down-stream pipes are smooth
and without deposits or scaling of welding beads.

3. Straight, unimpeded inlet and outlet runs
D = Meter size (Nominal Dia. DN)

CONTROL VALVE

BALL/GATE VALVE
(FULLY OPEN)

2 X 90

0

BENDS

3-DIMENSIONAL
(SAME FOR 3 X 90

0

BENDS)

2 X 90

0

BENDS

90

0

BENDS

OR “T” PIEC

Part A system installation and start-up

1. Description

2. Installation in the pipeline

2.1 General

S I Z E

φ

∆φ

S I Z E

φ

∆φ

D N

( m m )

m m

(inch)

m m

(inch)

D N

(inch)

m m

(inch)

m m

(inch)

1 0 S 8.9

(0.35)

0.4

(0.016)

3 / 8 " S 8.9

(0.35)

0.4

(0.016)

1 0 1 2 . 6

(0.50)

0.4

(0.016)

3/8" 1 2 . 6

(0.50)

0.4

(0.016)

1 5 1 4 . 9

(0.59)

0.4

(0.016)

1/2" 1 4 . 9

(0.59)

0.4

(0.016)

2 0 2 0 .9

(0.82)

0.4

(0.016)

3/4" 2 0 . 9

(0.82)

0.4

(0.016)

2 5 2 8 . 5

(1.12)

0.4

(0.016)

1 " 2 6 . 7

(1.05)

0.4

(0.016)

4 0 4 3 . 1

(1.70)

0.4

(0.016)

1/5" 4 0 . 9

(1.61)

0.4

(0.016)

5 0 5 4 . 5

(2.15)

0.6

(0.024)

2 " 5 2 . 6

(2.07)

0.6

(0.024)

8 0 8 2 . 5

(3.25)

0.6

(0.024)

3 " 7 8

(3.07)

0.6

(0.024)

1 0 0 1 0 7 . 1

(4.22)

0.6

(0.024)

4 " 1 0 2 . 4

(4.03)

0.6

(0.024)

1 5 0 1 5 9 . 3

(6.27)

0.8

(0.031)

6 " 1 5 4 . 2

(6.07)

0.8

(0.031)

2 0 0 2 0 6 . 5

(8.13)

1

(0.039)

8 " 2 0 2 . 7

(7.98)

1

(0.039)