7.6 Electrical data for outputs and inputs of the Ex versions
In-head transmitter (Ex version)
Rail-mount transmitter (Ex version)
Output terminals 5, 6 1
Input terminals 1, 2, 3, 4 2
Max. voltage to
transmitter
U
i
= 30 VDC
Max. voltage from
transmitter
U
o
= 30 VDC
Max. current to
transmitter
I
i
= 100 mA
Max. current from
transmitter
I
o
= 25 mA
Max. power to
transmitter
P
i
= 900 mW
Max. power from
transmitter
P
o
= 188 mW
Internal inductance
L
i
~ 0 mH
Max. inductance (input
loop)
L
o
~ 50 mH
Internal capacitance
C
i
~ 1 nF
Max. capacitance
(input loop)
C
o
~ 66 nF
Output terminals 5, 6 1
Input terminals 1, 2, 3, 4 2
Max. voltage to
transmitter
U
i
= 30 VDC
Max. voltage from
transmitter
U
o
= 30 VDC
Max. current to
transmitter
I
i
= 100 mA
Max. current from
transmitter
I
o
= 27 mA
Max. power to
transmitter
P
i
= 900 mW
Max. power from
transmitter
Not specified
Internal inductance
L
i
~ 0 mH
Max. inductance (input
loop)
L
o
~ 50 mH
Internal capacitance
C
i
~ 1 nF
Max. capacitance
(input loop)
C
o
~ 52 nF
1 Current loop
2 Intrinsically safe sensor connection