TECHNICAL DATA

46

OPTITEMP TT 10 C/R

www.krohne.com

02/2013 - 4000752703 - MA OPTITEMP TT 10 C/R R03 en

Rail-mount transmitter (Non-Ex)

7.4 Temperature data for potentially explosive areas

In-head transmitter (Ex version)

Dimensions

[mm]

[inches]

a

17.5

0.69

b

90

3.54

c

58

2.28

d

45

1.77

e

35

1.38

Temperature class

Ambient temperature T

a

T6

-40°C ≤ T

a

≤ +40°C / -40°F ≤ T

a

≤ +104°F

T5

-40°C ≤ T

a

≤ +55°C / -40°F ≤ T

a

≤ +131°F

T4

-40°C ≤ T

a

≤ +85°C / -40°F ≤ T

a

≤ +185°F

.book Page 46 Tuesday, February 26, 2013 1:43 PM