TECHNICAL DATA

7

43

OPTITEMP TT 10 C/R

www.krohne.com

02/2013 - 4000752703 - MA OPTITEMP TT 10 C/R R03 en

7.2 Technical data

INFORMATION!

The following data is provided for general applications. If you require data that is more
relevant to your specific application, please contact us or your local sales office.

Additional information (certificates, special tools, software,...) and complete product
documentation can be downloaded free of charge from the website (Download Center).

Measuring system

Application range

Temperature measurements in an industrial environment.

Design

Versions

Versions

Versions

Versions

TT 10 C

In-head transmitter for RTD input, optionally available in an intrinsically safe

version for installation in potentially explosive areas (zone 0).

TT 10 C T/C

In-head transmitter for thermocouple input, not available as intrinsically

safe version.

TT 10 R

Rail-mount transmitter for RTD input, not available as intrinsically safe

version.

TT 10 R T/C

Rail-mount transmitter for thermocouple input, not available as intrinsically

safe version.

Special feature

Special feature

Special feature

Special feature

Sensor break monitoring

User-definable output: ≤ 3.6 mA or ≥ 23 mA

Measuring accuracy

Accuracy

Calibration: ± 0.1% of span

Linearity: ± 0.1% of span

Cold Junction Compensation (CJC)

for TT 10 T/C

±

1.0 °C / ±1.8 °F

Temperature influence

Pt100: ± 0,024% of span per °C

Thermocouple: ± 0,024% of span per °C plus temperature influence CJC
±

0,05°C per °C

Operating conditions

Temperature

Temperature

Temperature

Temperature

In-head transmitter

Operating and storage temperature:

Operating and storage temperature:

Operating and storage temperature:

Operating and storage temperature:

Non-Ex version: -40...+85°C / -40...+185°F

Ex version: -40...+85°C / -40...+185°F (storage temperature), for detailed

information about the ambient temperatures refer to

Temperature data for

potentially explosive areas on page 46.

Rail-mount transmitter

Operating and storage temperature:

Operating and storage temperature:

Operating and storage temperature:

Operating and storage temperature:

-20...+70°C / -4...+158°F

Humidity

5...95% RH (non-condensing)

Protection category

Protection category

Protection category

Protection category

In-head transmitter

IP20 (with cover), IP10 (without cover)

Rail-mount transmitter

IP20