TECHNICAL DATA

44

OPTITEMP TT 10 C/R

www.krohne.com

02/2013 - 4000752703 - MA OPTITEMP TT 10 C/R R03 en

Installation conditions

Mounting

In-head transmitter: "B connection head" or larger according to DIN 43729;

with the help of the rail mounting kit you can also fix this transmitters on a

DIN rail according to EN 60715 TH35 (formerly EN 50022) ( refer to

Rail

mounting kit for in-head transmitters on page 18).
Rail-mount transmitter: rail according to EN 60715 TH35 (formerly EN

50022), 35 mm / 1.38".

For detailed information refer to chapter "Installation".

Weight

In-head transmitter (Non-Ex and Ex version): 40 g / 0.09 lb

Rail-mount transmitter: 55 g / 0.12 lb

Dimensions

For detailed information refer to

Dimensions on page 45.

Materials

Housing

In-head transmitter: PC (Non-Ex), Zinc alloy + PC (Ex version)

Rail-mount transmitter: PC + Glassfibre

Flammability acc. to UL

V0 (all versions)

Electrical connections

Power supply

Power supply

Power supply

Power supply

In-head transmitter: 6.5...32 VDC (Non-Ex version), 8.5...30 VDC (Ex version)

Rail-mount transmitter: 6.5...32 VDC

Galvanic isolation

No

Connection

Single/stranded wires: max. 1.5 mm

2

/ AWG 16

Polarity protection

Standard for all versions

Inputs / Outputs

Input

Input

Input

Input

Pt100 (IEC 60751, α=0.00385)

Type of connection: 3-wire

Span: 50/100/150/200/300/400/500°C and 100/200/300/400/600/800/1000°F

Zero point: -50...+50°C / -60...+120°F

Fine adjustment of span: ±10% of span (±5% for 600, 800 and 1000°F)

Thermocouple

Configuration span: 9 mV to 55 mV continuous

Corresponding to:

T/C J: 170-950 °C / 305-1710 °F

T/C L: 165-900 °C / 300-1620 °F

T/C K: 220-1370 °C / 400-2470 °F

T/C N: 290-1300 °C / 520-2340 °F

T/C T: 200-400 °C / 360-720 °F

Zero point: ±10% of span

Output

Output

Output

Output

Output signal

4...20 mA, temperature linear, 2-wire connection

4...20 mA, mV linear, 2-wire connection

Update time

≤ 200 ms

Permissible load

In-head (Non-Ex) and rail-mount transmitter: 700 Ω at 24 VDC and 25 mA

In-head transmitter (Ex): 620 Ω at 24 VDC and 25 mA

NAMUR compliance

NAMUR NE 21 (for frequencies ≥ 150 kHz)

.book Page 44 Tuesday, February 26, 2013 1:43 PM