beautypg.com

Table 2-2. bop terminations and controls, Bop terminations and controls -3, Ble 2-2 – KEPCO BOP-HV User Manual

Page 23

background image

BOPHV 112211

2-3

TABLE 2-2. BOP TERMINATIONS AND CONTROLS

NO.

NAME OF FUNCTION

FUNCTION

NOTE: NUMBERS CORRESPOND TO THOSE SHOWN IN FIGURE 2-2

1

A-C POWER

A-C input Power Switch and Indicator Lamp

2

OUTPUT

Output “READY” lamp energized when a-c power is turned on. If lamp goes off
when a-c power is applied, the internal protection circuit disables the output
and front panel controls. To restore full operation it is necessary to turn the
power supply OFF and then ON again after a few seconds.

3

± OUTPUT, COMMON, GROUND

Output and grounding terminals (parallel with rear barrier strip terminals)

4

MODE

Operating mode selector switch for “VOLTAGE” OR “CURRENT” mode

5

Mechanical voltmeter zero adjustment

6

Mechanical ammeter zero adjustment

7

VOLTAGE LIMIT

LED lamp, indicating voltage limiting operation

8

± VOLTAGE LIMIT

Controls for manual adjustment of the (±) voltage limits
BOP 500M BOP 1000M
A = 500V TO 0 -1000V TO 0
B = 0 TO +500V 0 TO +1000V

9

EO INPUT

Programming input terminals for voltage pre-amp

10

BIPOLAR VOLTAGE CONTROL

“ON-OFF” switch and voltage control for manual adjustment of the BOP d-c
output voltage (with switch “ON”)

11

EO METER

d-c output voltmeter (reads also average a-c signals)

12

EO MODE

LED lamp, indicating voltage mode operation

13

CURRENT LIMIT

LED lamp, indicating current limiting operation

14

± CURRENT LIMIT

Controls for manual adjustment of the (±) current limits
BOP 500M BOP 1000M
A = -80mA to 0 -40mA to 0
B = 0 to +80mA 0 to +40mA

15

IO INPUT

Programming input terminals for current pre-amp

16

BIPOLAR CURRENT CONTROL

“ON-OFF” switch and current control for manual adjustment of the BOP d-c
output current (with switch “ON”)

17

IO METER

d-c output ammeter (reads also average a-c signals)

18

IO MODE

LED lamp, indicating current mode operation

19

FUSE

a-c power fuse. Protects primary a-c input circuit

20

a-c power input jack. Accepts 3-wire line cord (supplied)

21

Cable holder, accepts output, sensing and ground wires for feed-through from
terminals through safety cover

22

REAR TERMINALS

Rear barrier strip with output, sensing and ground terminals

23

INTERLOCK

Shuts off BOP if safety cover is removed. Can be defeated by a forward pull

24

INT. IOX CONTROL

R303, compensation adjustment. See Section 5.

25

REAR CONNECTOR

Access to internal circuitry for programming connections

26

INT. CONTROLS

R31, R36, Current and voltage pre-amp zero controls

27

INSULATED TOOL

Use this tool for all internal adjustments