Buoy Transceiver
15
FIGURE 9. Setting the buoy/transceiver address
4.3
CONNECTING POWER TO THE TRANSCEIVER AND SENSOR
1. Use a screwdriver to remove the cover from the battery box.
2. Connect the black lead to the black terminal.
3. Connect the white or red lead to the red terminal. If the system is
functioning properly, you will hear the brush motor power on for a few
seconds.
4. Replace the battery box cover.
FIGURE 10. Connecting the battery terminals
Switch 2 value = 2
Switch 3 value = 4
Switch 5 value = 16
2 + 4 + 16 = 22
22 is the address
Switch 3 value = 4
Switch 7 value = 64
4 + 64 = 68
68 is the address
Switch 4 value = 8
Switch 6 value = 32
Switch 8 value = 128
8 + 32 + 128 = 168
168 is the address
Switch 2 value = 2
Switch 3 value = 4
Switch 4 value = 8
Switch 5 value = 16
2 + 4 + 8 + 16 = 30
30 is the address