Chaptertitle - chapter 6 specifications, Heading1 - 6.1 overview, Heading1 - 6.2 specifications – In-Situ Aquaculture Aerator Controller Manual User Manual
Page 21: Body, Chapter 6, 1 overview, 2 specifications, Chapter 6 specifications
Specifications
21
Chapter 6
Specifications
6.1
OVERVIEW
The Aqua Con TROLL
®
controller is a radio-linked, AC relay controller.
Models are available with 4 or 8 relays, with corresponding AC current
sensor inputs, encased in steel or fiberglass enclosures.
6.2
SPECIFICATIONS
Component Description
AC line-powered, microprocessor-controlled, radio-linked, AC relay
controller and AC current measuring system.
Controller Operating Temperature
0 to 50 °C (32 to 122 °F); 95% relative humidity, non-condensing
Controller Storage Temperature
–10 to 60 °C (14 to 140 °F); 95% relative humidity, non-condensing
Enclosure
Steel, Type 1, 3R
or
Fiberglass, NEMA 4X
Power Requirements
100–240 V
~
, 0.15 A, 50–60 Hz
AC Relay Outputs
24-240 VAC 10 A
Current Sensor Inputs
200 mA max.
Controller Dimensions
Steel models: 12.5 X 13.3 X 6.5 in (31.8 X 33.8 X 16.5 cm) (w X h X d)
Fiberglass models: 11.8 x 13.8 x 7.0 in (30.0 x 35.1 x 17.8 cm)
Note: Antenna adds an additional 6.3 in (16.0 cm) to height of each
Controller Weight
Steel models: 22.6 lb. (10.3 kg)
Fiberglass models: 15.5 lb. (7.0 kg)
Certifications
Listed for use in general locations to UL and CSA safety standards by ETL