beautypg.com

Caution – HT instruments HT157 User Manual

Page 21

background image

HT155 - HT157

EN - 19

5. Press the “

” key to start measuring. After this operation, the instrument:

 Starts measuring from the minute indicated in the system date/time and shows this

reference in column “hh:mm” with the relevant values of the quantities read in real
time

 Shows the message “Run” on the display
 In line 1, it shows the measuring time “Tm” instead of the indication of the set range
 Disables the possibility of accessing the programming menu by pressing the “ ” key.

Stops measuring to enter the programming menu again

6. Once the measuring time has elapsed, the instrument:

 Shows the indication “Wait” on the display, to indicate that it is waiting to start

(instant “00”) in the new measuring interval at the hour following the initial one (see
) (e.g.: if measurement is started at 8:49, the second measurement will be started at
9:49:00)

 Shows the measuring range again instead of the measuring time “Tm”
 This operation is repeated for each of the remaining 24 intervals

Fig. 16: Screen of instrument waiting to start a new recording (Wait)

CAUTION

When a measurement is in progress (Run) or waiting (Wait), the

”,“

”,“ ”,“

”,“

” keys are not active and it is necessary to stop or

cancel measurement to activate them again


7. With the flashing cursor on the “

” icon, press the “

” or “

” keys to access the

graphic display of the measure. The instrument displays the following screen:

Initial line

Central lines

Final line

Fig. 17: Screen of graphic display in 24Hours mode

This manual is related to the following products: