beautypg.com

General specifications, L maximum voltage between, C~40 – GW Instek GDM-356 User Manual

Page 26: C(32, F~104, F); storage : -10, C~50, C( 14, F~122, F). l relative humidity : 75% @ 0

background image

26

General Specifications

l Maximum voltage between

any

Terminals and

Grounding : 1000V rms.
l

Fused Protection for

mA Input Terminal : 0.5A, 250V fast
type, 5x20mm.
l

Fused Protection for 20A

Input Terminal : Un-fused.
l Range : Manual ranging.
l Maximum Display : Display :1999.
l Mesaurement Speed : Updates 2~3 times/second.
l Temperature : Operating: 0

o

C~40

o

C

(32

o

F~104

o

F);

Storage : -10

o

C~50

o

C( 14

o

F~122

o

F).

l Relative Humidity : 75% @ 0

o

C~30

o

C;

50% @ 31

o

C~40

o

C.

l Altitude: Operating : 2000m;
Storage : 10000m.
l Battery Type : 9V NEDA1604 or 6F22
or 006P.
l Battery Deficiency : Display “ ”.
l Data Holding : Display “ ”
l Negative reading : Display “ “
l Overloading : Display “1”.
l Dimensions (HxWxL) : 165x80x38.3mm.
l Weight : Approx.275g (battery
included).
l Safety/Compliances : IEC61010 CAT II 1000V
overvoltage and double
insulation standard.
l Certificate :

GDM-356