beautypg.com

Specifications – Detcon 1000 User Manual

Page 9

background image

Mdl 1000 H2S E-Chem / Inst. Air

Model 1000 H2S E-Chem w Instrument Air

Rev. 1.1

Page 5 of 28

2. Specifications


Sensor Type
Electrochemical

cell

Measurement Range
0-10ppm

H

2

S, up to 0-10,000ppm H

2

S

Accuracy/Repeatability

±10% of reading or ±0.5ppm, whichever is greater

Response/Clearing Time

T80 < 1 minute

Operating Temperature

-40°F to +122°F: -40°C to +50°C

Outputs

Linear 4-20mA DC; RS-485 Modbus™; 3 relays (alarm 1, alarm 2, and fault), Contacts rated 5 amps

Input Voltage
110~220VAC;

10~30VDC

Power Consumption

700mA (16.8 watts)

Electrical Classification

Explosion Proof; Class I, Division 1, Groups C, D

Sensor Life/Warranty

Sensor: 6 month conditional warranty; Transmitter: 2 year warranty

Analyzer Weight
70

lbs.

Dimensions

29” X 29” X 8”