View sensor status – Detcon IR-700 User Manual
Page 22

Model IR-700
IR-700 Instruction Manual
Rev. 3.1
Page 18 of 40
Restore Defaults
Navigating Program Mode
From Normal Operation, enter Program Mode by holding the magnet over PGM2 for 10 seconds. Note, the
“” prompt will show that the magnetic switch is activated during the 10 second hold period. The ITM will
enter Program Mode and the display will scroll the first menu item “View Sensor Status”. To advance to the
next menu item, hold the magnet over PGM1 or PGM2 while the current menu item’s text is scrolling. At the
conclusion of the text scroll the “”prompt (“” for PGM2 or “” for PGM1) will appear, and immediately
remove the magnet. The ITM will advance to the next menu item. Repeat this process until the desired menu
item is displayed. Note, PGM1 moves the menu items from right to left and PGM2 moves the menu items
from left to right.
To enter a menu item, hold the magnet over PGM1 or PGM2 while the menu item is scrolling. At the
conclusion of the text scroll the “”prompt (“” for PGM2 or “” for PGM1) will appear, continue to hold
the magnet over PGM1 or PGM2 for an additional 3-4 seconds to enter the selected menu item. If there is no
magnet activity while the menu item text is scrolling (typically 4 repeated text scrolls), the ITM will
automatically revert to Normal Operation.
3.5.1
View Sensor Status
View Sensor Status displays all current configuration and operational parameters including: sensor type,
software version number, detection range, AutoSpan level, days since last AutoSpan, estimated remaining
sensor life, gas factor, gas type, input voltage, 4-20 output, active counts, reference counts, and sensor ambient
temperature.
From the View Sensor Status text scroll, hold the magnet over PGM1 or PGM2 until the “” prompt appears
and continue to hold the magnet in place for an additional 3-4 seconds (until the display starts to scroll “Status
Is”). The display will scroll the complete list of sensor status parameters sequentially:
Sensor Model Type
The menu item appears as: “Model IR-700”
Current Software Version
The menu item appears as: “Version 1.XX”
Gas Type
The menu item appears as: “Gas Type = CH4”
Range of Detection
The menu item appears as: “Range XXX”
Serial ID Address
The menu item appears as: “Serial ID XX”
AutoSpan Level.
The menu item appears as: “Auto Span Level XX”