SE Mode
ü
(UTG M multiple-echo probes only)
Switches from multiple-echo to single-echo mode:
- To detect pits and flaws
- To increase the measurement range
- To obtain thickness measurements in circumstances where
multiple-echo can not
Adjust Display Lo/Hi Range
-
Adjusts the minimum and maximum
displayed range for the B-Scan. Use the (-)(+) buttons to decrease/increase
gain. Note: This does not alter the instruments measuring range.
Clear Display - Press to clear the B-Scan display and start over.
Save Screen Capture - Press to capture and save an image copy of
the current display. The last 10 screen captures are stored in memory and
can be accessed when connected to a computer (see USB Drive pg. 29).
Display Menu - Press to display the Gage menu (pg. 9)
Exit - Press to close the B-Scan display. Press the Up button to
return to the B-Scan display.
B-Scan Menu
Use the Up (move left) and Down (move right) buttons to navigate.