COSA Xentaur Hygrocontrol Type 72 User Manual
Page 39
CONNECTION OF DIGITAL OUTPUTS
RS-232C, RS-232.TTL UND RS-485
AT DIFFERENT TRANSM TERMINALS :
6-pol. CONNECTOR (female):
RS-232
RS-485
PIN 1 : CTS
PIN 1: A*
PIN 2 : GND
PIN 2: GND
PIN 3 : RTS
PIN 3: A
PIN 4 : RxD
PIN 4: B*
PIN 5 : GND
PIN 5: GND
PIN 6 : TxD
PIN 6: B
FIXED CABLE OUTPUT:
RS-232
RS-485
white: CTS
wheit: A*
yellow: RTS
yellow: A
green: RxD
green: B*
brown: TxD
brown: B
grey:
GND grey:
GND
SCREW TERMINALS:
RS-232
RS-485
B 8-1 : CTS
B 8-1 : A*
B 8-2 : RTS
B 8-2 : A
B 8-3 : GND B 8-3 : GND
B 8-4 : RxD
B 8-4 : B*
B 8-5 : TxD
B 8-5 : B
Connect A-A* und B-B* if you
need a terminator! (154 OHMS)
CONNECTING OF POWER AT PLUG IN VERSIONS:
CONNECTING OF POWER AT SCREW TERMINAL VERSIONS:
23o VAC
23o VAC
12o VAC
12o VAC
24 VAC
24 VAC
12 VDC
12 VDC
24 VDC
24 VDC
6 - polig
4 - polig
10...33 VDC
10...33 VDC
N = PIN 1
PIN B1 = N1
PIN B1 = N1 PIN B1 = 0V
PIN B1 = 0V
PIN B1 = 0V
PIN B1 = N1
N = PIN 1
N = PIN 3
12V = PIN 4
24V = PIN 5
PIN B2 = 24V
+10...33 V = PIN 4
L = PIN 2
PIN B2 = L1
PIN B2 = L1 PIN B2 = 12V
PIN B2 = L1
L = PIN 3
L = PIN 2
0 V = PIN 6 0 V = PIN 6
GND (-) = PIN 5
PIN B2 = 10-33V
PE = PIN
PIN B3 = PE
PIN B3 = PE PIN B3 = PE
PIN B3 = PE
PIN B3 = PE
PIN B3 = PE
PE = PIN
PE = PIN
page C 5