Rt‐10 flow monitor – AW Gear Meters RT-10 User Manual
Page 14

RT‐10 Flow Monitor
Operation and Programming Manual
13
Grand Total Reset
As security against losing the Grand Total and overflow values, you must hold three keys simultaneously
for nine seconds to reset. You can only do this with the cover off. While viewing the Total display, press
and hold the SEL and DN and UP buttons for the full nine seconds. The display asks you if you are “SURE”
and counts down to reset.
1 SEC
D ISPLA YS
B RIEFLY
SEL*
GRA N D TO TA L
* PRESS
A N D
HO LD
SEL +
D N +
UP FO R
9 SEC .
M O D E
FRO M RA TE D ISPLA Y
M O D E
+ D N *
+ UP*
9 SEC
1 , 2 , 3 ...
TO C LO C K O R TO TA L D ISPLA Y
1 SEC
D ISPLA YS
B RIEFLY
SEL*
SEL + D N *
GRA N D TO TA L
# O F TIM ES
GRA N D TO TA L
HA S RO LLED
O VER FRO M
9 9 9 9 9 9 . TO 0
(M A X = 9 9 9 9 )
*
O VERFLO W
D ISPLA Y
W H ILE
PRESSED
M O D E
FRO M RA TE D ISPLA Y
M O D E
TO C LO C K O R TO TA L D ISPLA Y