AST AST44LP Datasheet User Manual
Intrinsically safe, Environmental data, Electrical data

American Sensor Technologies
•
450 Clark Dr., Mt. Olive, NJ 07828
•
phone (973) 448-1901
•
fax (973) 448-1905
•
email: [email protected]
TM
Environmental Data
Temperature
Operating
-40 to 80°C (-40 to 176°F)
Storage
-40 to 100°C (-40 to 212°F)
Thermal Limits
Compensated Range 0 to 55°C (32 to 132°F)
TC Zero
<±1.5% of FS
TC Span
<±1.5% of FS
Other
Shock
EN 60068-2-27
Vibration
EN 60068-2-6, 60068-2-64, and IEC 68-2-32
EMI/RFI Protection:
Yes
Rating:
IP-66
Electrical Data
Output
4-20mA
1-5VDC
1-6VDC
Excitation
10-28VDC
10-28VDC
10-28VDC
Output Impedance
>10k Ohms
<100 Ohms, Nominal
<100 Ohms, Nominal
Current Consumption:
20mA, typical
5mA, typical
5mA, typical
Bandwidth
(-3dB): DC to 250 Hz
(-3dB): DC to 1kHz
(-3dB): DC to 1kHz
Output Noise:
-
<2mV RMS
<2mV RMS
Zero Offset:
<±1% of FS
<±1% of FS
<±1% of FS
Span Tolerance:
<±2% of FS
<±1.5% of FS
<±1.5% of FS
Output Load:
0-800 Ohms@10-28VDC
10k Ohms, Min.
10k Ohms, Min.
Reverse Polarity Protection
Yes
Yes
Yes
Performance @ 25°C (77°F)
Accuracy*
< ±0.25% BFSL (< ±0.5% BFSL for 0-1 PSI)
Stability (1 year)
±0.25% FS, typical
Over Range Protection
2X Rated Pressure
Burst Pressure
5X or 75 PSI (whichever is less)
Pressure Cycles
> 100 Million
Applications
Industrial OEM Equipment
HVAC/R Equipment
Water Management
Control Panels
Pneumatics
Hydraulic Systems
Vapor Recovery
Data Loggers
External Tank Levels
Benefits
Class 1 Div 1 Groups C,D when installed
with an approved barrier
Class I Zone 0 Exia IIB T4 Ga
(Ta = -40°C to +80°C)
High Strength Stainless Steel Construction
No Internal O-rings
Wide Operating Temperature
Pressures from 0-1 to 0-15 PSI
Low Static and Thermal Errors
Unparalleled Price and Performance
Compatible with Wide Variety of Liquids
and Gases
The AST44LP is a stainless steel pressure transducer with a wide variety of
options. With its rugged construction and the best price-to-performance ratio
in the industry, the AST44LP is the solution for low pressure measurement in
Intrinsically Safe areas.
* Accuracy includes non-linearity, hysteresis & non-repeatability
AST44LP Low Pressure Transducer / Transmitter
For UL certified barrier drawing, see A01657.
For CSA certified barrier drawing, see A08949.
Intrinsically Safe