beautypg.com

AST AST46DS Datasheet User Manual

Explosion-proof, Pressure transducer / transmitter with display, Performance @ 25°c (77°f)

background image

TM

American Sensor Technologies

450 Clark Dr., Mt. Olive, NJ 07828

phone (973) 448-1901

fax (973) 448-1905

email: [email protected]

Performance @ 25°C (77°F)

Accuracy*

< ±0.25% BFSL

Stability (1 year)

±0.25% FS, typical

Over Range Protection

2X Rated Pressure

Burst Pressure

5X Rated Pressure or 45,000 PSI, whichever is less

Pressure Cycles

> 100 Million

Electrical Data

Output

4-20mA

1-5VDC

Excitation

8-28VDC

8-28VDC

Output Impedance

>10k Ohms

<100 Ohms, Nominal

Current Consumption:

25mA, typical

2mA, typical

Bandwidth

(-3dB): DC to 1kHz

(-3dB): DC to 1kHz

Output Noise:

-

<2mV RMS

Zero Offset:

<± 0.5% of FS

<± 0.5% of FS

Span Tolerance:

<± 1.0% of FS

<± 1.0% of FS

Output Load:

0-800 Ohms@8-28VDC

5k Ohms, Min.

Reverse Polarity Protection

Yes

Yes

AST46DS CSA Certified: Class I & II Division 1 & 2 | Class III

Environmental Data

Temperature

Operating

-40 to 85°C (-40 to 185°F)

Display Operating

-30 to 80°C (-22 to 176°F)

Storage

-55 to 105°C (-67 to 221°F)

Th

er

m

al

Limits

Compensated Range

0 to 55°C (30 to 130°F)

TC Zero

<±1.0% of FS

TC Span

<±1.0% of FS

Other

Shock

100G, 11 msec, 1/2 sine

Vibration

10G peak, 20 to 2000 Hz.

EMI/RFI Protection:

Yes

Enclosure Rating:

Suitable for Outdoor Use; Type 4X Rated

Pollution Degree

2 (interior of enclosure)

Measurement

(Installation) Category I
Altitude

2000m

Explosion-Proof

Pressure Transducer / Transmitter with Display

AST46DS explosion proof pressure transducers features the latest advances in

transducer technology. With a power supply as low as an 8VDC and low current

consumption, the AST46DS can operate in remote areas with minimal power. The

re-zeroing function, allows for field calibration in a safe environment to further enhance

well site or system readings. Pressure ranges are available up to 20,000 PSI; these

explosion-proof pressure transducers and transmitters are designed for all common oil
and gas pressures from shallow to deep wells.

Explosion Proof: Class I & II Division 1 / 2 Groups A, B, C, D, E, F, G

ƒ

Class III Division 1 & 2

ƒ

ANSI/ISA 12.27.01-2003 Single Seal Approved

ƒ

ABS (American Bureau of Shipping) Approved

ƒ

Display Units: PSI | Bar | kpa | Mpa | kg/cm

ƒ

2

| in WC | Volts | mA

Applications

SCADA systems

ƒ

Wellhead systems

ƒ

Compressor systems and

ƒ

stations

Pipeline instrumentation

ƒ

Power generation equipment

ƒ

Offshore platforms

ƒ

Oil and gas pressure

ƒ

monitoring

Test systems

ƒ

Benefits

Low current consumption voltage output

ƒ

Re-zero push-button functionality

ƒ

Display pressure units or output signal

ƒ

Accurate, repeatable sensor technology

ƒ

Rugged design withstands harsh outdoor

ƒ

environments

Available in exotic alloys

ƒ

High quality, NEMA 4X case and finish

ƒ

withstands salt spray and outdoor environments