The AST5400 differential pressure (DP) transducer can measure line pressures up

to 5,000 PSI with a turndown ratio of 15 to 1. Using Krystal Bond™ Technology, the

AST5400 contains no silicone oil, O-rings, or welds. This MEMS pressure sensor

technology completely isolates the media to the pressure ports, thus eliminating

contamination risk. The low strain level on the diaphragm results in accurate,

repeatable measurements. The AST5400 can be used to measure differential

pressure across a filter, monitor level in a sealed or vented tank, or calculate flow

across an orifice plate.

With its digital compensation, this series offers excellent linearity and performance

over temperature. The electronics now offer a fail safe condition on the output

signal. If the transducer were to experience a fault condition, the transducer can

be programmed to rail the output signal to 10% below the minimum or 10% above

maximum output signal to notify the user of an issue and protect the system

from undesirable conditions. The AST5400 also offers excellent flexibility in its

configuration, allowing for a variety of wetted materials and pressure ports.

AST5400

Differential Pressure (DP) Transducer

Performance @ 25°C (77°F)

Total Error Band*

<± 1% of Line Pressure

Maximum Line Pressure

2,000 PSI (140 Bar)

Proof Pressure

2X Line pressure**

Burst Pressure

5X Line pressure

Pressure Cycles

> 100 Million

Environmental Data

Temperature

Operating

-20 to 70ºC ( -4 to 158ºF)

Storage

-50 to 125ºC (-58 to 257ºF)

Thermal Limits

Compensated Range

-20 to 70ºC ( -4 to 158ºF)

Other

Shock

100G, 10msec, 1/2 sine

Vibration

10G peak, 20 to 2000Hz

EMI/RFI Protection:

Yes

IP Class:

IP-66; IP-67 Optional

Electrical Data

Output

4-20mA

1-5V, 0-5V, 1-6V

1-10V, 0-10V

0.5-4.5V Ratiometric

Excitation

10-28VDC

10-28VDC

15-28VDC

5VDC, Regulated

Current Consumption

-

< 15mA

< 15mA

< 15mA

Sampling Rate

200Hz

200Hz

200Hz

200Hz

Output Noise

< 1mV, RMS

< 1mV, RMS

< 1mV, RMS

< 1mV, RMS

Output Load

0-800 Ohms@10-28VDC

5k Ohms, min.

5k Ohms, min.

5k Ohms, min.

Reverse Polarity Protection

Yes

Yes

Yes

Yes

Applications

Aerospace

ƒ

Building Automation

ƒ

Fuel Systems

ƒ

Hydraulics

ƒ

Hydrogen (316L only)

ƒ

Labs / Metrology

ƒ

Medical

ƒ

Military Vehicles

ƒ

HVAC/R Systems

ƒ

Desalination Equipment

ƒ

(Inconel718 Recommended)

Benefits

Krystal Bond™ Technology

ƒ

ASIC compensation

ƒ

Turn-down capability

ƒ

Both or either pressure port can see full

ƒ

line pressure - No expensive balancing valves
required!

Line pressure up to 5,000 PSI (350 Bar)

ƒ

Smart electronics with failure condition

ƒ

protection

Wide variety of materials for a variety of media

ƒ