AST AST46HA Datasheet User Manual
Explosion-proof, Environmental data, Electrical data
TM
American Sensor Technologies
•
450 Clark Dr., Mt. Olive, NJ 07828
•
phone (973) 448-1901
•
fax (973) 448-1905
•
email: [email protected]
Environmental Data
Temperature
Operating Ambient
-40 to 85°C (-40 to 185°F)
Operating Media
-55 to 125°C (-65 to 250°F)
Storage
-55 to 105°C (-67 to 221°F)
Thermal Limits
Compensated Range
-20 to 70°C (-4 to 158°F)
TC Zero: <±0.5% FS
TC Span: <±0.5% FS
Other
Shock
EN 60068-2-27
Vibration
EN 60068-2-6, 60068-2-64, and IEC 68-2-32
EMI/RFI Protection:
Yes
Rating:
IP-65 (vented), IP-66(factory sealed)
Applications
Well Optimization
Oil and Gas Pipelines
Drilling Platforms
Marine & Offshore
CNG / Hydrogen Fill Stations
Paint Booths
Remote Telemetry Unit
Cold Climate Drilling & Mining
Panel Instrumentation
Benefits
ANSI/ISA-12.27.01.2003 Certified “Single Seal”
(no secondary seal required)
ABS (American Bureau of Shipping) Approved
ASIC Compensation
Superb Temperature Performance
Wide Operating Temperature
Excellent Accuracy
High Proof and Burst Pressure
Available in Exotic Alloys (Consult Factory for
Inconel 718 or Hastelloy C276)
Constructed with a simple-yet-rugged design, the AST4600 Explosionproof Pressure
Transducer/Transmitter stands up to a variety of applications where price and
performance are critical.
Factory Sealed Gauge Pressure Transducer
Pressures from 100 to 20,000 PSI
•
CSA approved for use in hazardous areas including:
•
UL1203/FM3615 Class I Zone 1 Group IIC
▪
Class I Div 1 Groups A, B, C, D Explosionproof
▪
Class II Div 1 Groups E, F, G Dust Ignition-proof
▪
Vented Gauge Pressure Transducer
Pressures from 1 to 1,000 PSI Gauge
•
CSA approved for use in hazardous areas including:
•
Class I Zone 1 Group IIC
▪
Class I Div 1 Groups A, B, C, D Explosionproof
▪
Explosion-Proof
AST46HA High Accuracy 0.1% Pressure Transducer
Performance @ 25°C (77°F)
Accuracy*
<±0.1% BFSL
Stability (1 year)
±0.1% FS, typical
Over Range Protection
+
2X Rated Pressure
Burst Pressure
5X Rated Pressure
Pressure Cycles
> 100 Million
* Accuracy includes non-linearity, hysteresis & non-repeatability,
+
For higher proof pressures, contact factory
Electrical Data
Output
4-20mA
0-5V, 1-5V, 1-6V
0-10V, 1-10V
0.5-4.5V Ratiometric
Excitation
10-28VDC
10-28VDC
15-30VDC
5VDC, Regulated
Current Consumption
-
<10mA
<10mA
<10mA
Sampling Rate
400Hz
400Hz
400Hz
400Hz
Output Noise
<1mV, RMS
<1mV, RMS
<1mV, RMS
<1mV, RMS
Zero Offset
<±0.5% FS
<±0.5% FS
<±0.5% FS
<±0.5% FS
Span Tolerance
<±0.5% FS
<±0.5% FS
<±0.5% FS
<±0.5% FS
Output Load
0-800 Ohms@10-28VDC
5k Ohms, min.
5k Ohms, min.
5k Ohms, min.
Reverse Polarity Protection
Yes
Yes
Yes
Yes