American Sensor Technologies

450 Clark Dr., Mt. Olive, NJ 07828

phone (973) 448-1901

fax (973) 448-1905

email: [email protected]

TM

Electrical Data

Output

4-20mA

1-5VDC

0.5-4.5V Ratiometric

Excitation

10-28VDC

10-28VDC

5VDC, regulated

Output Impedance

>10k Ohms

<100 Ohms, Nominal

<100 Ohms, Nominal

Current Consumption:

20mA, typical

3mA, typical

3mA, typical

Bandwidth

(-3dB): DC to 250 Hz

(-3dB): DC to 1kHz

(-3dB): DC to 1kHz

Output Noise:

-

<2mV RMS

<2mV RMS

Zero Offset:

<±1% of FS

<±1% of FS

<±1% of FS

Span Tolerance:

<±1% of FS

<±1% of FS

<±1% of FS

Output Load:

0-800 Ohms@10-28VDC

10k Ohms, min

10k Ohms, min

Reverse Polarity Protection

Yes

Yes

Yes

Environmental Data

Temperature
Operating

0 to 60°C (32 to 140°F)

Storage

0 to 80°C (32 to 176°F)

Thermal Limits
Compensated Range

0 to 55°C (32 to 131°F)

TC Zero: <±2.0% of FS

TC Span: <±2.0% of FS

Other
Shock

100G, 11 msec, 1/2 sine

Vibration

10G peak, 20 to 2000 Hz.

EMI/RFI Protection:

Yes

Rating:

IP-68

Fill Fluids

Glycol / Silicone Oil

Performance @ 25°C (77°F)

Accuracy*

< ±0.5% BFSL

Over Range Protection

2X Rated Pressure

Burst Pressure

5X or 1,250 PSI (whichever is less)

Pressure Cycles

> 50 Million

* Accuracy includes non-linearity, hysteresis & non-repeatability

PVDF/PTFE Submersible Pressure Transducer

AST4530

For CSA certified barrier

drawing, see A08949.

Applications

Chemical totes

ƒ

Salt water holding tanks

ƒ

Process plants

ƒ

Rail-car liquid level

ƒ
monitoring

Storage tanks

ƒ

Benefits

ABS (American Bureau of Shipping) Approved

ƒ

Class I Zone 0 Exia IIB T4 Ga

ƒ
(Ta = 0°C to +60°C)

Excellent liquid and gas compatibility

ƒ

Cost effective alternative to ultrasonic & radar

ƒ
sensor technologies

Works with reflective liquids

ƒ

Will not fail due to vapor

ƒ

No galvanic corrosion or risk of bacteria

ƒ

The AST4530 submersible pressure transducer is constructed using PVDF

material and a PTFE diaphragm. Designed to measure liquid level of corrosive

liquids, the AST4530 features submersible PVDF cable, cord grip and housing.

The AST4530 features a conduit connection for turbulent installations such as

on-board ships, turbulent tanks, and rail cars.
Voltage and 4-20mA output signals allow users to interface for low current

consumption or long distance transmission applications.

The AST4530 is CSA157 certified to Class I Div 1, Groups C and D for use in

intrinsically safe areas with an approved barrier, ANSI/ISA 12.27.01 Single Seal

Approved and ATEX Exia IIB Class I, Zone 0, T4.
CAN/CSA C22.2 No 60079-0:11, ANSI/ISA 60079-0:09, CAN/CSA E60079-11:02,

ANSI/ISA 60079-11:11, CAN/CSA C22.2N.157-92, UL 913 (6th Edition)