AST AST20PT Datasheet User Manual
Precision pressure & temperature transmitter, Environmental data, Electrical data
TM
American Sensor Technologies
•
450 Clark Dr., Mt. Olive, NJ 07828
•
phone (973) 448-1901
•
fax (973) 448-1905
•
email: [email protected]
Environmental Data
Operating Ambient Temperature
-40 to 85°C (-40 to 185°F)
Operating Media Temperature
-55 to 125°C (-67 to 257°F)
Storage Temperature
-50 to 125°C (-58 to 257°F)
Thermal Limits
Compensated Range
0-70°C (32 to 158°F)
TC Zero
< ± 0.5% FS
TC Span
< ± 0.5% FS
Other
Shock
100G, 11msec, 1/2 sine
Vibration
10G peak, 20 to 2000Hz
EMI/RFI Protection:
Yes
Rating:
IP-66
Electrical Data
Output
4-20mA
+
0-5V, 1-5V
0-10V, 1-10V
0.5-4.5V Ratiometric
Excitation
10-28VDC
10-28VDC
15-30VDC
5VDC, Regulated
Current Consumption:
-
< 10mA
< 10mA
< 10mA
Sampling Rate
400Hz
400Hz
400Hz
400Hz
Output Noise:
< 1mV, RMS
< 1mV, RMS
< 1mV, RMS
< 1mV, RMS
Zero Offset
< ± 0.5% FS
< ± 0.5% FS
< ± 0.5% FS
< ± 0.5% FS
Span Tolerance
< ± 0.5% FS
< ± 0.5% FS
< ± 0.5% FS
< ± 0.5% FS
Output Load:
0-800 Ohms@10-28VDC
5k Ohms, min.
5k Ohms, min.
5k Ohms, min.
Reverse Polarity Protection
Yes
Yes
Yes
Yes
Applications
Aerospace
Analytical Instruments
Hydraulics
Hydrogen (Consult factory
for media compatibility)
Labs / Metrology
Medical
Military
Test Stands
Benefits
ASIC Compensation
Superb Temperature Performance
Real Time Thermal Compensation
Real Time Linearity Correction
Turndown Capability
The AST20PT is a digitally compensated pressure and temperature dual
output transmitter, offering measurments from a single process point,
reducing process penetration points and leaks. Krystal Bond™ Technology
alone offers excellent non-linearity and non-repeatability performance. When
it is combined with the ASIC, the AST20PT steps into its own league of high
performance pressure sensing at an affordable price.
AST20PT
Precision Pressure & Temperature Transmitter
Performance @ 25°C (77°F)
Accuracy*
< ±0.1% BFSL (<±0.2% BFSL over 15,000 PSI)
Stability (1 year)
±0.1% FS, typical
Proof Pressure **
2X Rated Pressure, standard
Burst Pressure
5X or 50,000 PSI, whichever is less
Pressure Cycles
> 100 Million
* Accuracy includes non-linearity, hysteresis & non-repeatability **For higher proof pressures, contact factory
+
For units with loop-powered 4-20mA output, the pressure loop must be powered or the temperature output will not operate.