beautypg.com

Ordering information pressure ranges wiring, Pressure ranges, Pressure psi – AST AST46PT Datasheet User Manual

Page 2: Pressure code v ented, Pressure code factory sealed

background image

TM

www.astsensors.com

© 2014 American Sensor Technologies Inc. AST46PT 01/30/2014.

All specifications subject to change without notice.

Ordering Information

Pressure Ranges

Wiring

Output

Power Connections Output Connections

Green

Length

Red

Black

White

Blue

Voltage +V Supply -V Supply Pressure Temp.

Case

Ground

4.3"

4.68"

4-20mA +Pressure -Pressure -Temp.

+Temp.

Case

Ground

4.8"

5.18"

For U.S. installations, sensor case ground (green wire) must be

bonded to ground according to Article 501 & 505 of the NEC.

Pressure Ranges

++

2.5 and 7.5 PSI units must be ordered in inches of H

2

O

Pressure PSI

0-1

Pressure Code V

ented

G

0001

Pressure PSI

0-100

Pressure Code Factory Sealed

0

0100

0-2.5

++

G

0069

0-200

0

0200

0-5

G

0005

0-500

0

0500

0-7.5

++

G

0208

0-1,000

0

1000

0-10

G

0010

0-1,500

0

1500

0-15

G

0015

0-2,500

0

2500

0-25

G

0025

0-3,000

0

3000

0-50

G

0050

0-5,000

0

5000

0-100

G

0100

0-7,500

0

7500

0-200

G

0200

0-10,000

1

0000

0-500

G

0500

0-15,000

1

5000

0-1,000

G

1000

0-20,000

2

0000

Pressure Unit

B= Bar

K= kg/cm

2

P= PSI

Wetted Material

0= 17-4PH 1= 316L 2= Inconel 718

+

4= Hastelloy C276

+

Series Type

Insert Pressure Code

AST46PT

A

0500

P

3

1

000

T

G

+

Consult factory on availability

Electrical

T= 2ft. 18 AWG wires

U= 4ft. 18 AWG wires W= 2 Meter 18 AWG wires

Outputs

1= 0.5-4.5V ratiometric

2= 0-5V

3= 1-5V

4= 4-20mA

5= 0-10V

6= 1-6V

G= 1-10V

Pressure Range

G= Gauge Pressure**

V= Gauge Pressure (Vacuum Calibrated)**

0= Sealed Gauge up to 9,999 PSI

1= Sealed Gauge up 10,000 to 19,999 PSI

2= Sealed Gauge 20,000 PSI

** Not suitable for Class II

H

Failure State

H= High L= Low N= None

Process Connection*

A= 1/4" NPT Male (up to 10,000 PSI)

I= 1/4" NPT Female (up to 15,000 PSI)

P= 1/2" NPT Male (up to 15,000 PSI)

W= F250C Female Autoclave (10,000 to 20,000 PSI)

* for other ports contact factory, "W" not available in 316L

1

Temperature Output

1= -40 to 85°C (-40 to 185°F)

2= -40 to 125°C (-40 to 257°F)

3= 0 to 70°C (32 to 158°F)

4= -55 to 125°C (-67 to 250°F)

5= -18 to 93°C (0-200°F)

Options

000= No Options

Approval

-Z= Add “-Z” for CRN Registered to ANSI/ASME B31.3. Contact factory for material, pressure, and process connection options.

-Z