Pressure ranges, Ordering information ast4500, Ast4510 – AST AST4510 Datasheet User Manual
Page 2
www.astsensors.com
TM
© 2014 American Sensor Technologies Inc. AST4500/4510 06/18/2014.
All specifications subject to change without notice.
Pressure Ranges
+
Ordering Information
AST4500
PSIG
Pressure Code
Feet of Water Column @ 4ºC (approx.)
0-100
00100
230.67
0-50
00050
115.33
0-30
00030
69.20
0-20
00020
46.13
AST4510
0-15
00015
34.60
0-10
00010
23.07
0-7.5*
00208*
17.30
0-5
00005
11.53
0-2.5*
00069*
5.77
0-1
00001
2.31
+
All pressures between 0-1 PSI and 0-100 PSI are available. Please consult factory. *2.5 and 7.5 PSI Sensor must be ordered in inches of H
2
O.
N
Options Cable Lengths:
140= 15 ft. (4.6 m)
075= 20 ft. (6.1 m)
074= 25 ft. (7.6 m)
004= 35 ft. (10.7 m)
130= 40 ft. (12.2 m)
065= 50 ft. (15.2 m)
003= 100 ft. (30.5 m)
050= 150 ft. (45.7 m)
Wetted Material
1= 316L / 304 / Hytrel Cable / Kynar Cord Grip
Electrical
N= Conduit fitting, Cable 6 ft.
P= Conduit fitting, Cable 10 ft.
X= Optional Length (see options)
Outputs
3= 1-5V
4= 4-20mA (2 wire loop powered)
Pressure Unit
B= Bar
H= Inches H
2
O
K= kg/cm
2
P= PSI
Pressure Measurement
Insert 5-digit pressure code
Process Connection
L= Cone
Series Type
AST4510
L
00005
P
4
1
000
-SS
Approval
(Left Blank)= UL ANSI/ISA 12.12.01 Class I Div 1 Intrinsically Safe Groups C, D (formerly UL913)
-SS= Add “-SS” for CSA157 Class I Div 1 Groups C, D Intrinsically Safe and ANSI/ISA 12.27.01 Single Seal Approval and SIRA ATEX Exia IIB
Class I, Zone 0, T4
Note: CSA approved products require case/earth ground electrical connection.
See wiring installation sheet for further details