beautypg.com

Pressure ranges, Ordering information ast4500, Ast4510 – AST AST4510 Datasheet User Manual

Page 2

background image

www.astsensors.com

TM

© 2014 American Sensor Technologies Inc. AST4500/4510 06/18/2014.

All specifications subject to change without notice.

Pressure Ranges

+

Ordering Information

AST4500

PSIG

Pressure Code

Feet of Water Column @ 4ºC (approx.)

0-100

00100

230.67

0-50

00050

115.33

0-30

00030

69.20

0-20

00020

46.13

AST4510

0-15

00015

34.60

0-10

00010

23.07

0-7.5*

00208*

17.30

0-5

00005

11.53

0-2.5*

00069*

5.77

0-1

00001

2.31

+

All pressures between 0-1 PSI and 0-100 PSI are available. Please consult factory. *2.5 and 7.5 PSI Sensor must be ordered in inches of H

2

O.

N

Options Cable Lengths:

140= 15 ft. (4.6 m)

075= 20 ft. (6.1 m)

074= 25 ft. (7.6 m)

004= 35 ft. (10.7 m)

130= 40 ft. (12.2 m)

065= 50 ft. (15.2 m)

003= 100 ft. (30.5 m)

050= 150 ft. (45.7 m)

Wetted Material

1= 316L / 304 / Hytrel Cable / Kynar Cord Grip

Electrical

N= Conduit fitting, Cable 6 ft.

P= Conduit fitting, Cable 10 ft.

X= Optional Length (see options)

Outputs

3= 1-5V

4= 4-20mA (2 wire loop powered)

Pressure Unit

B= Bar

H= Inches H

2

O

K= kg/cm

2

P= PSI

Pressure Measurement

Insert 5-digit pressure code

Process Connection

L= Cone

Series Type

AST4510

L

00005

P

4

1

000

-SS

Approval

(Left Blank)= UL ANSI/ISA 12.12.01 Class I Div 1 Intrinsically Safe Groups C, D (formerly UL913)

-SS= Add “-SS” for CSA157 Class I Div 1 Groups C, D Intrinsically Safe and ANSI/ISA 12.27.01 Single Seal Approval and SIRA ATEX Exia IIB

Class I, Zone 0, T4

Note: CSA approved products require case/earth ground electrical connection.

See wiring installation sheet for further details