Workmanship - AST, Inc. pressure transmitters have a limited one-year warranty to the original purchaser. AST, Inc. will replace or repair,

free of charge, any defective transmitter. This warranty does not apply to any units that have been modified; misused, neglected or installed

where the application exceeds published ratings. AST’s sensors are made with pride in New Jersey, USA. If in the area please feel free to

stop by for a visit!

Installation/Applications - The purchaser is responsible for media compatibility, functional adequacy, and correct installation of the transmitter.

TM

www.astsensors.com

© 2012 American Sensor Technologies Inc. AST2000-H2 12/18/12.

All specifications subject to change without notice.

Warranty

Dimensional Data

Ordering Information

Series
Pressure Ports

F= 7/16-20 UNF Male [SAE 4]

M= 3/8-24 UNF Male [SAE 3]

X= Special (see option code 487)
Pressure Range

+

00020= 20 Bar

00448= 448 Bar

00500= 500 Bar

00700= 700 Bar

00900= 900 Bar
Pressure Unit

B= Bar

Output

1 = 0.5-4.5V ratiometric [5VDC supply]

Electrical

F= Packard Metripack 150

Wetted Material

1= 316L

Options

000= No Options

384= High Accuracy

487= 1/2-20 UNF Stud for high pressure H

2

storage

AST2000 F 00500 B 1 F 1 000

Test Performed

The tests preformed are marked as "X" in the following table. The test

conditions, parameters, and details are described in the Annex 1. (Test

Report) to Technical Report No. KS1011296 dated 2011-01-04.

No.

Type of Test

EU 406/2010

Annex IV

Remark

1

General Requirements Part 3 Sect. 2

X

2

Technical

Requirements

Part 3 Sect. 3

X

3

Hydrogen

Compatibility Test

Part 3 Sect. 4.1.1

X

4

Ageing Test*

Part 3 Sect. 4.1.2

X

5

Ozone Compatibility

Test**

Part 3 Sect. 4.1.3

Not

Applicable

6

Corrosion Resistance

Test

Part 3 Sect. 4.2.1

X

7

Endurance Test

Part 3 Sect. 4.2.2

X

8

Hydraulic Pressure

Cycle Test

Part 3 Sect. 4.2.3

X

9

Internal Leakage Test

Part 3 Sect. 4.2.4

Not

Applicable

10

External Leakage Test Part 3 Sect. 4.2.5

X

11

Isolation Resistance

Testing

ECE R110 Rev. 1

X

12

EMC Compatibility

Testing

ECE R110 Rev. 1

X

13

Review of Information

Documentation

EU 406/2010 Annex

II Part 1

X

* Test applies only for non-metallic materials ** Test applies only to elastomer

materials where either a sealing surface is exposed directly to air or if used as a

flexible fuel line cover.

+

3/8-24 UNF Male [SAE 3] is only available for 20 bar and 448 bar