beautypg.com

Water connection, Danger – Alliance Laundry Systems UW35PV User Manual

Page 31

background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Specifications and Dimensions

29

F232084

Water Connection

Connections should be supplied by hot and cold water
lines of at least the sizes shown in the Water Supply
Line Sizing table. Installation of additional machines
will require proportionately larger water lines. Refer to
Table 6. Flush the water lines before connecting them
to the machine.

To avoid personal injury, recommended
inlet water temperature should be no
higher than 125
° Fahrenheit (51° Celsius).

W709

DANGER

UWPV Pocket Hardmount
Water Supply Information

Specifications

35

60

80/100

125/150

Number of main fill water inlets

2

2

2

2

Main fill water inlet size, in (mm)

0.5 (12.7)

0.75 (19)

0.75 (19)

1 (25.4)

Number of Spray Rinse water inlets

2

2

2

2

Spray rinse water inlet size, in (mm)

0.5 (12.7)

0.5 (12.7)

0.75 (19)

0.75 (19)

Recommended pressure psi (bar)

30 – 85 (2 – 5.7)

Inlet flow capacity (80 psi), gal/min
(l/min)

28 (106)

39 (148)

50 (189)

75 (284)

Table 5