Specifications and Dimensions

27

F232084

For UW125PV and UW150PV Models Only

IMPORTANT: Do not block the overflow vent
above the drain line.

If water or suds flow from the overflow vent and the
machine has been verified to be operating properly
with proper water levels and correct amount of laundry
chemicals, a drain line may be added to the vent and
routed to a drain trough.

1. Remove the riveted bracket on the rear panel for

access to the overflow vent pipe.

2. Route a drain pipe from the vent pipe to a drain

trough. Drain pipe should be routed straight
across or down and be suspended above drain
trough by at least 3 inches (7.62 cm).

IMPORTANT: Do not route the overflow vent pipe
to a direct drain system.