1.

This document supersedes all other information provided by Triton for ATM installation for accessibil-
ity.

2.

Information provided in this manual is based on federal guidelines (ADA Accessibility Guidelines for
Buildings and Facilities – ADAAG) as amended through January 1998. You should verify it has not
been amended. States may also have accessibility codes. These codes may be more restrictive than the
federal guidelines. Please verify this with the state where the ATM is to be installed prior to installation.
For state contact information, you may call the ADA information line at 1-800-514-0301.

3.

For countries other than the US, please use the guidelines for accessibility for that country.

4.

A complete copy of the ADAAG referred to here can be found at http://www.access-board.gov. In-
cluded in this document is the section of the ADAAG specifically for ATMs. For additional information
on floor surfaces and other ADAAG requirements, please see the complete specification.

4.34

Automated Teller Machines.

4.34.1

General. Each automated teller machine machine required to be accessible by 4.1.3 (Accessible

Buildings: New Construction) shall be on an accessible route and shall comply with 4.34 (Automated
Teller Machines).

4.34.2

Clear Floor Space. The automated teller machine shall be located so that clear floor space comply-

ing with 4.2.4 (Clear Floor or Ground Space for Wheelchairs) is provided to allow a person using a
wheelchair to make a forward approach, a parallel approach, or both to the machine.

4.34.3

Reach Ranges.

(1) Forward Approach Only. If only a forward approach is possible, operable parts of all controls shall be
placed within the forward reach range specified in 4.2.5 (Forward Reach).

(2) Parallel Approach Only. If only a parallel approach is possible, operable parts of controls shall be
placed as follows:

(a) Reach Depth Not More Than 10 inches (255 mm). Where the reach depth to the operable parts of all
controls as measured from the vertical plane perpendicular to the edge of the unobstructed clear floor space at
the farthest protrusion of the automated teller machine or surround is not more than 10 inches (255 mm), the
maximum height above the finished floor or grade shall be 54 inches (1370 mm).

(b) Reach Depth More Than 10 inches (255 mm). Where the reach depth to the operable parts of any control
as measured from the vertical plane perpendicular to the edge of the unobstructed clear floor space at the farthest
protrusion of the automated teller machine or surround is more than 10 inches (255 mm), the maximum height
above the finished floor or grade shall be as follows: