The ATM is quite tolerant of power line variations.
However, AC power for the terminal should come
from a dedicated source with an isolated ground.
Route the AC power cord and the phone cord
out through the hole in the back of the cabinet
and install the split ring grommet into the hole.
Attach the ground cable to the dispenser.
9.
Connect the AC input plug to the wall outlet (See
Note below and section on connecting power and
communications cables before proceeding with
Step 10).
**IMPORTANT**
•
Electrical rating of the ATM: 200-250 VAC, 50-60 Hz, 2.60 amps.
•
The ATM is designed to work on an IT (Isolated Terra)-type power system having a phase-to-
phase voltage not exceeding 250 volts.
•
The AC socket-outlet shall be installed near the equipment and shall be easily accessible.
POWER SUPPLY CORD - SPECIFICATIONS
For European applications, the power supply cord must conform to the following
specifications:
1.)
Two-conductor with Protective Earth (PE) ground.
2.)
IEC 320 molded connector on one end and molded plug on the other
end.
3.)
Certified for country of installation.
4.)
Rated minimum H05VV-F with minimum 0.75 mm
2
(except where specific
countries require 1.0 mm
2
) conductors.
5.)
Maximum length: 3 meters.
Figure 4. Installing the dispensing
mechanism.
7.
Refer to Figure 4. Install the dispensing mechanism
by sliding the end with the circuit board into the
tray in the cabinet. The mechanism should slide
under two tabs in the rear and the front edge slots
should align with the two bolts provided with wing
nuts. Once the mechanism is fully engaged into
the tray, tighten the wing nuts by hand.
Ground
Connection