308.3
Side Reach.
308.3.1 Unobstructed. Where a clear floor or ground space allows a parallel approach to an element and
the side reach is unobstructed, the high sidereach shall be 48 inches (1220 mm) maximum and the low side
reach shall be 15 inches (380 mm) minimum above the finish floor or ground.
Figure 308.3.1 Unobstructed Side Reach
308.3.2 Obstructed High Reach. Where a clear floor or ground space allows a parallel approach to an
element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (865
mm) maximum and the depth of the obstruction shall be 24 inches (610 mm) maximum. The high side reach
shall be 48 inches (1220 mm) maximum for a reach depth of 10 inches (255 mm) maximum. Where the reach
depth exceeds 10 inches (255 mm), the high side reach shall be 46 inches (1170 mm) maximum for a reach
depth of 24 inches (610 mm) maximum.
EXCEPTIONS:
1. The top of washing machines and clothes dryers shall be permitted to be 36 inches (915 mm) maximum
above the finish floor.
2. Operable parts of fuel dispensers shall be permitted to be 54 inches (1370 mm) maximum measured from
the surface of the vehicular way where fuel dispensers are installed on existing curbs.
EXCEPTIONS:
1. An obstruction shall be permitted between the clear
floor or ground space and the element where the depth
of the obstruction is 10 inches (255 mm) maximum.
2. Operable parts of fuel dispensers shall be permit-
ted to be 54 inches (1370 mm) maximum measured from
the surface of the vehicular way where fuel dispens-
ers are installed on existing curbs.
Figure 308.3.2 Obstructed High Side Reach