TESTING OPERATION
1.
NOTE: Float switch on/off level has been preset
but should be checked by viewing through the toilet
inlet.
Temporarily connect the pump discharge pipe to the
house drain pipe and plug in pump
Temporary
Connection
To house
Drain
GFCI
Outlet
Toilet
Inlet
1
4 in.
Water
2. Fill the tank with 4 in. of water. Be sure the pump does
not turn on.
2
3. Add an additional 1/2 in. of water to the tank. The pump
should turn “ON” when the water level reaches 4-1/2
in. If “ON” level is correct, unplug pump, disconnect
temporary discharge piping and proceed to next section.
If “ON” level is incorrect, refer to Troubleshooting on
page 18.
4-1/2 in.
Water
3
See also other documents in the category Star Water Systems Pumps:
- 2STFAL20 (Flint & Walling) (6 pages)
- HPP360 (5 pages)
- HPP360 (2 pages)
- 2SUEL (6 pages)
- COND1 (6 pages)
- CS511 (Flint & Walling) (12 pages)
- S1503 (2 pages)
- S1503 (24 pages)
- 3STS (2 pages)
- 5SDHL (2 pages)
- 3SDHL (6 pages)
- 2SPHAL (2 pages)
- SB12DCC (Flint & Walling) (8 pages)
- 433047 (8 pages)
- 4ER (8 pages)
- 3CDH (11 pages)
- 3SVS (Flint & Walling) (2 pages)
- 3CEH (2 pages)
- 3SVS (Flint & Walling) (2 pages)
- S1108 (8 pages)
- S1585 (8 pages)
- S1104 (8 pages)
- 50TC (4 pages)
- S1101 SERIES (1 page)
- SJ05 (22 pages)
- Convertible Jet Pump (2 pages)
- SJ05S (1 page)
- SJ05S (9 pages)
- SW Jet Pump (1 page)
- ES05S (20 pages)
- SJ05SAT20H (9 pages)
- SJ05SAT20H (2 pages)
- VA SERIES (8 pages)
- Star 4in Sub Instr2&3-wire (11 pages)
- Lawn Pump (1 page)
- HSP10P1 (22 pages)
- HSPJ100 (Flint & Walling) (4 pages)
- FW0520 Gas Pump (12 pages)
- CJ103 (Flint & Walling) (21 pages)
- HCP05 (5 pages)