Seed Hawk TOOLBAR 2010 User Manual
Page 55
Seed Hawk Manual
Tool Bar
Page 52
SYMPTOM
POSSIBLE CAUSE
SOLUTION
Shanks do not
maintain trip/packing
pressure in hilly
terrain.
The “IN” pressure gauge indicates
less than 1200 lb
f
/in
2
(8 275 kPa).
Inspect quick couplers to ensure
complete engagement.
Excessive field operating speed.
Reduce field operating speed.
Note: Trip/packing pressure may be
momentarily increased by activating
hydraulic Circuit #1 while passing
through a shallow dip in the terrain.
Intermittent electrical power
supply to shank solenoid coil.
Ensure all electrical connections are
fully engaged and no open electrical
circuits to coil.
Shanks will not go
down under pressure
Pivot points are too tight or
seized.
Loosen up pivot points about 1/8 of a
turn. Don’t over loosen them.