0 trouble-shooting – Seed Hawk TOOLBAR 2010 User Manual
Page 53

8.0 TROUBLE-SHOOTING
Seed Hawk Manual
Tool Bar
Page 50
SYMPTOM
POSSIBLE CAUSE
SOLUTION
Can not adjust shank 
pressure. 
Incomplete engagement of 
hydraulic quick couplers 
Inspect quick couplers to ensure 
complete engagement. 
Meter Wheel Switch not set to 
“ON”. 
Ensure that both the Meter Wheel 
Switch and Main Power Switch are 
“ON”. 
Lock valves for shanks are set in 
closed position. 
Ensure that both lock valves, one at 
the manifold and one at the tractor 
quick coupler, are set to the open 
position. 
No electrical power to shank 
solenoid valve. 
Check for broken wire in harness to 
solenoid coil. 
No electrical power to shank 
pressure adjustment motor. 
Check for broken wire to shank 
pressure adjustment motor. 
Shank relief motor seized.
Release set screw on collar and to 
increase pressure turn clockwise and 
to decrease pressure turn counter 
clockwise. 
Tractor hydraulic selector valve 
not holding pressure. 
Disconnect coupler at Circuit #1. If 
pressure is now adjustable, repair the 
tractor selector valve.(make sure the 
lever is in working position not float) 
Solenoid coil malfunctioning.
Activate solenoid valve manual 
override. If the shank pressure 
responds properly, replace the coil 
also check for power going to coil. 
 Shank Solenoid valve cartridge 
contaminated. 
Remove solenoid valve cartridge per 
repair instructions in the 
MAINTENANCE section of this 
Operator’s Manual, inspect to make 
sure all orings are not damaged, then 
clean and replace. 
Shank pressure gauge 
malfunctioning. 
Remove and replace pressure gauge 
if not responding to increase and 
decrease of pressure 
Shank orifice blocked.
Remove cap and orifice and check to 
see if contamination is block off 
orifice. Clean out and reinstall. 