Weighing with measurement of BMI, body fat and body water

The seca 804 can also calculate the following body data in addition to weight: Body Mass

Index, body fat and body water proportion. For this purpose, an imperceptible, harmless

AC electric current is passed through the body and the measured values classified by

weight, gender, build and height. These data must previously have been entered in the

scale (see “Storing personal data” on page 12).
So that your values are determined correctly and are comparable with one another over

several days, please note the following instructions:
• You should perform the measurement

barefoot, otherwise there is insufficient

contact with the sensors (in this case

Err 2

will appear in the display). If you

have very dry skin, moisten your feet

slightly to improve conductivity.

• Stand as still as possible during meas-

urement.

• Position both feet so that they are as

much in contact with the sensors as

possible (see Fig. 6).

• Enter your height as exactly as possi-

ble. An error of just 2.5 cm will lead to

a deviation of 1 litre body water in the

calculation!

• Wherever possible, perform the meas-

urements each day at the same time

and under the same conditions, e.g. 15

minutes after getting up. Measure-

ments taken directly after sleeping give

implausible results, because body wa-

ter is distributed differently throughout

the body during sleep.

• Measurements taken directly after

strenuous physical exercise also give

implausible results. Take a relatively

long break (approximately 2-3 hours)

before measuring.

• Heavy meals or drinking of alcohol also

give implausible results.

• In the following cases, exact measure-

ments cannot be performed using the
seca 804

: during pregnancy or if your

body contains medical implants such

as artificial joints, metal plates or

screws. In such cases, you should

have your doctor carry out a differential

diagnostic examination to obtain cor-

rect results.

Storing personal data

The seca 804 can store personal data for up to four different people. In addition, it is pos-
sible to perform a measurement in so-called Guest Mode (see “Measuring in Guest Mode”

on page 14). The four personal memories are each assigned to one of the four keys

MENU

, ▲, ▼ or SET, and can subsequently be selected using these keys when the scale

is switched on.
– Switch on the scale using the one of the

four keys (MENU, ▲, ▼ or SET) to the

memory of which the personal data is

to be assigned.

se(a

,

8.8.8.8.8.

and

0.00

appear con-

secutively in the display. The scale is

then automatically set to zero and

ready to use. The display likewise

shows the symbol for the selected per-

sonal memory, e.g. .

– Keep the MENU key depressed until

HEIGHT appears in the display.
The display will show the most recently-

entered height.

– You can change the value in the incre-

ments shown by the graduations in the

display using arrow keys ▲ and ▼.

– Once the correct value has been set,

briefly press the SET key.
The menu for gender and build

appears.

– Use arrow keys ▲ and ▼ to select your

gender and your build:
MALE NORMAL: male, normal build,

(exercising a maximum of twice a week

for 30 minutes),