2/01

Model S05 Non-Metallic Design Level 1 Page 25

DUAL PORTING OPTIONS

Several dual porting options are

possible. The pump can be converted
to a dual port arrangement on both the
suction and the discharge ends. The
porting can be configured to a single
suction and a dual discharge. The porting
can be changed to a dual suction and a
single discharge.

The above changes are possible

because the porting flange of the elbows
(items 17) are designed to mate with
½" NPT or ½" BSPT (tapered)
connection.

Dual porting of both suction and
discharge ends of the pump

Converting the pump from the

standard single suction and discharge
porting configuration to dual porting at
each end is easy. Simply remove the
manifold seals and manifolds (items 33
and 22 from pump assembly drawing)
from the pump.

The discharge elbows and suction

elbows can be rotated 90° increments
(see arrows and optional positioning in
the Dual Porting Drawing.

Single porting of the suction and
dual porting of the
pump discharge

To convert the pump from the

standard single suction and single
discharge porting configuration to a dual
discharge porting arrangement remove
the only the discharge manifolds and
manifold seals. Position the discharge
elbows in the desired direction at 90°
increments. (See arrows and optional
positioning in the Dual Porting Drawing.)

Dual porting of the suction and
single porting of the pump
discharge

To convert the pump from the

standard single suction and single
discharge porting configuration to a dual
suction porting arrangement remove the
only the suction (bottom) manifolds and
manifold seals.

Position the suction elbows in the

desired direction at 90° increments. (See
arrows and optional positioning in the
Dual Porting Drawing.)

NOTE: See Repair Parts List on next page.

Read these instructions
completely, before in-
stallation and start-up. It
is the responsibility of
the purchaser to retain

this manual for reference. Failure to
comply with the recommendations stated
in this manual will damage the pump, and
void factory warranty.