SANDPIPER S05 Non-Metallic User Manual
Page 27
520-211-000
2/01
Model S05 Non-Metallic Design Level 1 Page 25
DUAL PORTING OPTIONS
Several dual porting options are
possible. The pump can be converted
to a dual port arrangement on both the
suction and the discharge ends. The
porting can be configured to a single
suction and a dual discharge. The porting
can be changed to a dual suction and a
single discharge.
The above changes are possible
because the porting flange of the elbows
(items 17) are designed to mate with
½" NPT or ½" BSPT (tapered)
connection.
Dual porting of both suction and
discharge ends of the pump
Converting the pump from the
standard single suction and discharge
porting configuration to dual porting at
each end is easy. Simply remove the
manifold seals and manifolds (items 33
and 22 from pump assembly drawing)
from the pump.
The discharge elbows and suction
elbows can be rotated 90° increments
(see arrows and optional positioning in
the Dual Porting Drawing.
Single porting of the suction and
dual porting of the pump discharge
To convert the pump from the
standard single suction and single
discharge porting configuration to a dual
discharge porting arrangement remove
the only the discharge manifolds and
manifold seals. Position the discharge
elbows in the desired direction at 90°
increments. (See arrows and optional
positioning in the Dual Porting Drawing.)
Dual porting of the suction and
single porting of the pump
discharge
To convert the pump from the
standard single suction and single
discharge porting configuration to a dual
suction porting arrangement remove the
only the suction (bottom) manifolds and
manifold seals.
Position the suction elbows in the
desired direction at 90° increments. (See
arrows and optional positioning in the
Dual Porting Drawing.)
NOTE: See Repair Parts List on next page.
Read these instructions
completely, before in-
stallation and start-up. It
is the responsibility of
the purchaser to retain
this manual for reference. Failure to
comply with the recommendations stated
in this manual will damage the pump, and
void factory warranty.
IMPORTANT