beautypg.com

2 introduction, 1 appropriate use, 2 scope of delivery – LumaSense Technologies IS 310 User Manual

Page 9: 3 technical data

background image

IS 310 / IGA 310 Manual

Controls and Installation 9

2 Introduction

2.1 Appropriate use

The IS 310 and IGA 310 are stationary pyrometers for non-contact temperature measurement of
metallic surfaces, graphite, ceramics, etc.

2.2 Scope of delivery

Instrument, works certificate, and user manual.

Note: A connection cable is not included with the instrument and has to be ordered

separately (see Chapter 7, Reference numbers).

2.3 Technical data

Temperature ranges:

IS 310

IGA 310

650 ... 1800 °C (MB 18)
800 ... 2300 °C (MB 23)
1100 ... 2500 °C (MB 25)

300 ... 1300 °C (MB 13L)
500 ... 1500 °C (MB 15)

Spectral Range:

IS 310

0.8 ... 1.1 µm (Si photo detector)

IGA 310

1.45 ... 1.8 µm (InGaAs photo detector)

Power supply:

24 V DC ± 25% stabilized, ripple < 50mV
5 ... 30 V DC for LED targeting light (I 30 mA)

Output:

4 ... 20 mA load independent current, linear to temperature
Max load: max. 500 at 24 V

max. 200 at 18 V
max. 800 at 30 V

Emissivity:

0.2 ... 1; adjustable

Accuracy:

( = 1, T

amb.

= 23 °C)

Up to 1500 °C: 0.8% of measured value + 1 °C

Above 1500 °C: 1% of measured value + 1 °C

Repeatability:

0.3% of measured value

( = 1, T

amb.

= 23 °C)

Response time t

90

:

10 ms

Sighting:

LED targeting light

Housing:

Stainless steel

Weight:

215 g

Ambient temperature:

0 ... 70 °C

Storage temperature:

-20 ... 70 °C

Mounting position:

Any

Protection class:

IP65 (DIN 40050)

Connection cable:

2 m - 30 m, with connector

CE label:

According to EU-directives about electromagnetic immunity