INSTALLATION

ETHERNET / DEVICENET MODULE

A-3

Install the DeviceNet bulkhead connector by removing
the plastic plug covering the circular hole (ITEM 4) in
the front lower panel assembly. Install the 5-pin con-
nector and mounting plate over the mounting studs as
shown in detail. Fasten with two of the supplied lock
nuts.

Install the Ethernet bulkhead connector by removing
the plastic plug covering the circular hole (ITEM 5) in
the front panel assembly. Locate the EtherNet bulk-
head connector. Remove the nut off the back of the
bulkhead connector and assemble it in the hole (con-
nector from bottom, nut from top, do not over tighten).
Plug the CAT5 cable into the bulkhead connector.

Place the Ethernet / DeviceNet Interface Module
(ITEM 1) onto the self-clinching studs in the position
shown in figure A-1.

Fasten the module to the door assembly using three
of the supplied lock nuts (ITEM 2).

Install the plastic LED lens through the open hole in
the front of the door assembly and roll the rubber ring
onto lens from the rear of the door assembly (ITEM 3).

Seat the status LED into the lens from the rear of the
door assembly.

When Wire Drive Interface Module is not installed,
use Figure A-1
, locate the 4-pin to 6-pin interconnect.
Insert the interconnect between J73(4-pin) Figure A-1
on the Ethernet module and J16(6-pin) in the machine
harness. Discard the 4-pin to 4-pin interconnect and
proceed to board setup.

When Wire Drive Interface Module is installed, use
Figure A-2
, locate the 4-pin to 4-pin interconnect.
Insert the interconnect between J73 (4-pin) Figure A-2
on the Ethernet module and J81 (4-pin) on the Wire
Drive Interface Module. Discard the 4-pin to 6-pin
interconnect.

BOARD SETUP

DeviceNet Baud rate: The default Baud rate is 125K.
If another Baud rate is desired, reference table 1 in
and set switches 1 and 2 of bank S2. Every device on
a DeviceNet network must have the same Baud Rate.

DeviceNet Baud Rate (Table 1)

Switch 1

Switch 2

Baud Rate

Off

Off

125K

On

Off

250K

Off

On

500K

On

On

Programmable Value

DeviceNet MAC ID: The default MAC ID is 62. Every
device on the DeviceNet network should have a
unique ID. If another MAC ID is desired, refer to Table
3 of this quick start guide/ to set switches 3 through 8
of bank S2.

COMPLETE BOARD INSTALLATION

• Close door assembly being careful to avoid cutting

or pinching any wires.

• Reinstall the screws in door assembly.

• Re-apply power and verify the appropriate status

lights on the Power Wave are green. Discard any
remaining hardware.

SOFTWARE INSTALLATION

• See SOFTWARE INSTALLATION Section.

FIGURE A-2

4-pin to 4-pin
interconnect

Wire Drive
Module

J81

J73

This manual is related to the following products: