beautypg.com

Programming the dialer – Hired-Hand Emergency Back-Up and Alarms: AVD-45b Automatic Voice Dialer User Manual

Page 11

background image

- 11 -

Programming Tone/Pulse and PBX

1. Press the “M” key until “PROGRAM: NUMBERS” appears in the LCD, then press “2”.
2. Press “1” (YES) at the “PROGRAM: T-LINE” prompt.
3. Press “1” (TONE) for touch tone phone service.

Press “2” (PULSE) for pulse (rotary) phone service.

4. After selecting TONE or PULSE, the LCD will display “PROGRAM: PBX”.
5. Press “1” (ON) to set for PBX phone system, then enter the PBX digit 0-9 (This will allow the unit to

dial the PBX digit, wait for a dial tone, then dial the stored number).
Press “2” (OFF) to set for regular phone system (Waits for a dial tone, then dials the stored number).


Programming Exit and Entry Delay

1. Press the “M” key until “PROGRAM: NUMBERS” appears in the LCD, then press “2” three times.
2. Press “1” (YES) at the “PROGRAM: CHANNEL” prompt.
3. Press “1” (ON) for a 60 second Exit delay (This provides a 60 second exit delay, after the AVD-45b is

set in the “OPERATE” mode, before the unit will react to a sensor trip, allowing time to exit).
Press “2” (OFF) for no Exit delay (This will allow the unit, when set in the “OPERATE” mode, to react
immediately to a sensor trip.

4. After selecting the Exit delay, the LCD should display “ENTRY DELAY”.
5. Press “1” (ON) for a 20 second Entry delay (This provides a 20 second entrance delay, after any exit

delay time has elapsed, before the unit will react to a sensor trip, allowing time to shut off).

6. Press “2” (OFF) for no Entry delay (This will allow the unit to react immediately to a sensor trip, after

any exit delay has elapsed.

NOTE: When using the AVD-45b with an alarm panel that already has Exit/Entry delays
programmed, EXIT and ENTRY should be programmed for “OFF” unless an additional delay is
needed.

PROGRAMMING THE DIALER

This manual is related to the following products: