6 connecting ac power to the swine finisher, Ac power, Swine finisher – Hired-Hand Farm Hand Series: Swine Finisher User Manual
Page 22: Re t hot l1 l2, Inset a, Neutral ground hot, Ea r t h

Part No. 4801-0150 Rev 8-04
Farm Hand Swine Finisher 5 Stage
22 of 32
11.6 Connecting AC Power To the Swine Finisher
RE
T
HOT
L1
L2
EA
R
T
H
AC POWER
To Breaker
Inset A
AL
A
R
M N
.O
.
A
L
A
R
M
N
.C
.
5
4
3
2
1
IN
ST
A
G
E
S
3
2
1
SENSORS
+1
2V
SI
GN
AL
GND
RE
T
HO
T
L1
L2
EA
R
T
H
GN
D
LO
HI
5
4
3
2
1
FA
N
2
FA
N
1
IN
VAR FANS
STAGES OUT
SWX1
J5
J4
J3
J2
PRESSURE
AC POWER
HH NET
Curtain 1
Curtain 2
Cl
os
e
Op
e
n
Ho
t
Cl
os
e
Op
e
n
Ho
t
Signal
Signal
Swine Finisher
Inset A
Neutral
Ground
Hot
Note: If there is not a proper ground connection, the variable speed stages will
not operate correctly.
Note: If using 110 VAC, the neutral, or return, wire must be connected to terminal
L2. This will ensure proper operation of the variable speed stages.
See also other documents in the category Hired-Hand Equipment:
- Polar Cool: Portable Evaporative Cooling System (22 pages)
- Polar Cool: External Control Box (4 pages)
- Polar Cool: Pump & Float Replacement (2 pages)
- Polar Cool: PUMP REPLACEMENT (4 pages)
- Polar Cool: Wall Mount Kit (4 pages)
- Unitized Mega Cool (68 pages)
- Unitized Mega Cool: Square Bottom (63 pages)
- Mega-Cool: Square Reservoir (24 pages)
- Mega-Cool rev 6-09 (46 pages)
- Mega-Cool: Mega-Cool Pad Extender Kit (5 pages)
- Mega-Cool: Float Valve Replacement (1 page)
- Mega-Cool: Float Valve (Topaz) Replacement (1 page)
- Mega-Cool: In-Line Pump Motor Replacement (2 pages)
- Var-O-Matic (2 pages)
- System 1000 Power Vent (31 pages)
- System 1000 Power Vent (13 pages)
- System 500 Programs (Conventional Model) (5 pages)
- System 100 Variable Speed Controller (7 pages)
- System 500 Programs (Tunnel Model) (7 pages)
- System 1000 Power Curtain (17 pages)
- System 2000 AUTO TEMP (10 pages)
- System 2001 Power Curtain Controller (43 pages)
- System 500 Power Curtain Controller (31 pages)
- System 1000 Power Curtain Eight Stage Controller (34 pages)
- ICS-500 Environmental Controller (34 pages)
- Pressure Transducer Changeout (1 page)
- HH Software: HH.Net Router/Repeater (8 pages)
- HH Software: 900SS Wireless Network (10 pages)
- HH Software: Farm Manager (22 pages)
- HH Software: Data Shuttle Launch Pad (25 pages)
- Sens-O-Matic (Feed Hopper Switch) (2 pages)
- Manual Light Dimmer (2 pages)
- Electro Mechanical Controls (Relay-Switches): PHOTOHELIC POWER VENT (10 pages)
- Electro Mechanical Controls (Relay-Switches): PT Controller (9 pages)
- Electro Mechanical Controls (Relay-Switches): PC-DB Curtain Controller with DIF (6 pages)
- Electro Mechanical Controls (Relay-Switches): PC-DB Curtain Controller with Timer Override (7 pages)
- Electro Mechanical Controls (Relay-Switches): Photohelic Gauge (1 page)
- Feed Management System (15 pages)
- Contactor Control System (CCS): 4, 8, or 12 Stage (19 pages)
- Contactor Control System (CCS): Triple Pole 16-Stage (7 pages)
- Contactor Control System (CCS): Vent Machine Override 3 Wire PowerTrak (1 page)
- Evolution 4000 Control System (86 pages)
- Evolution Series 1200: Variable Output With Override Pot (14 pages)
- Evolution Series 1200: Variable Output (12 pages)
- Evolution Series 1200 (64 pages)