Figure 9 Install the Chamber

Framed
Opening

Chamber

Canopy

Roof

18 in (45.7 cm)

Flashing


5.9

Attach Winter Door

1. The Winter Door must be placed on the

opposite side from the Pulley Bracket
Assembly. See Figure 6. For ease of
installation, slide the door from the hinge
channel. See Figure 7. Then position the
hinge and channel on the inside of the
Chamber/Extension. Bolt using existing
hardware at each corner of the door. Slide the
Door into place after installing the hinge
bracket and channel.

5.10

Attach Cables to the Baffle

1. Referring to Figure 8, run the

Baffle Cables with and without
the spring down through the
Pulley Bracket Assembly.

2. Run the Door cable up and

around the Pulley Bracket
Assembly. See Section 8 for
cabling and pulley installation.

6.

Installing the

Chimney Vent in the Roof

This section covers the
necessary steps to install the
Chimney Vent into the roof of
the confinement building.
Assembly steps in Section 5
should be completed before
proceeding with Section 6.

6.1

Install the Chamber

1. See Figure 9. Construct a

framed opening in the roof that
is 26.5 inches (67.31 cm) by
26.5 inches (67.31 cm) for the
2 foot Vent. For the 3 foot Vent the
opening should be 38.5 inches (97.79 cm)
by 38.5 inches (97.79 cm).


2. Hoist the chamber up through the opening until

the top of the chamber extends 18 inches (45.7
cm) above the roof. See Figure 9.


3. Connect the chamber to the framed opening

using lag bolts that go through the
aluminum angle brackets at the corners of
the chamber. Drill appropriate pilot holes
for the lag bolts through the angle bracket
and foam.

Figure 6 Attach Pulley Bracket Assembly

Figure 7 Winter
Door

Slide Door

out of hinge

channel

This side of

door faces

outside

Figure 8 Attach Cables to Damper and Door

Pulley

Bracket

Assembly

Door Cable

Baffle Cable with

spring

Baffle Cable without

spring

Door

Baffle

Stop

Bolt