HATZ Diesel 4H50TIC User Manual
Page 40

Procedure
NOTICE
i
▪ After approx. 20 seconds the start procedure cuts off auto-
matically to protect the starter. If the engine is still not run-
ning after that, turn the starting key back to position "0" and
eliminate the cause (see the chapter 9.1 Fault table,
page 86).
▪ Turn the starting key to position "0" every time you want to
start the engine.
▪ The anti repeat device in the ignition lock makes it impossi-
ble for the starter to engage while the engine is running and
become damaged.
Step
Activity
1
Remove the protective cap (4) from the ignition lock.
2
Insert the starting key all the way and turn to position "I".
Depending on the model, the following indicators light up:
▪ Charge control (10)
▪ Oil pressure display (9)
▪ Pre glow display (6)
NOTE: If the optional engine temperature display (8) lights up,
the coolant temperature is impermissibly high. Do not start the
engine; eliminate the cause.
When the optional pre glow display (6) goes out, continue with
step 3.
3
Turn the starting key to position "II".
4
As soon as the engine is running, release the starting key.
▪ The starting key springs back to position "I" and remains in
this position during operation.
▪ The charge control (10) and oil pressure display (9) go out.
▪ The operating display (11) lights up.
NOTICE
i
▪ In case of irregularities, switch off the engine immediately.
▪ Identify the fault and eliminate it.
▪ For details of troubleshooting, see the chapter 9.1 Fault ta-
ble, page 86.
4H50TIC
Operation and use
HATZ
Operator's Manual
41