72 series, Bypass module data communication port, Selectable park light output – Ultra Start 72 Series User Manual
Page 4

SYSTEM PROGRAMMING - Menu 1
PAGE 4
INSTALL MANUAL
QUICK VIEW WIRE DIAGRAM
1
2
3
1
2
3
1
2
3
4
Position 1 or Position 2
GREEN
BLUE
N/A*
RED
BLACK
WHT/VIOLET
BYPASS MODULE DATA COMMUNICATION PORT
***FOR USE WITH COMPATIBLE BYPASS MODULES ONLY***
SELECTABLE PARK LIGHT OUTPUT
OUTPUT TO ACTIVATE DOOR LOCK CIRCUIT (-)
OUTPUT TO ACTIVATE DOOR UNLOCK CIRCUIT (-)
OUTPUT FOR VOLTAGE INVERTER*
12VOLT OUTPUT FOR BYPASS MODULE
GROUND OUTPUT FOR BYPASS MODULE
(-) WHILE RUNNING OUTPUT (BYPASS TURN ON) / STARTER DISABLE
* THE CENTER PIN OF THE KEYLESS CONNECTOR IS LOW CURRENT AND IS DESIGNED
TO SUPPLY POWER TO DOOR LOCK MODULES (DO NOT CONNECT TO RELAYS)
OVERLOADING THIS OUTPUT WILL DAMAGE THE MODULE!
**THIS CONNECTOR IS USED FOR ALARM MODELS ONLY.
*** FOR USE WITH COMPATIBLE BYPASS MODULES ONLY.
BY DEFAULT THE SYSTEM COMES WITH THE PARK
LIGHT JUMPER SET FOR POSITIVE PARK LIGHT
OUTPUT. TO CHANGE THE SYSTEM TO A NEGATIVE
PARK LIGHT OUTPUT, PLACE THE JUMPER IN THE
NEGATIVE PARK LIGHT POSITION SHOWN IN THE
DIAGRAM. (Position 2)
POSITIVE
PARK LIGHT
NEGATIVE
PARK LIGHT
72 SERIES