3 PUMP

CONNECTIONS

Do not use stainless steel, chrome or nickel plated pipe with the

flexible hose push-in plumbing connections.

Do not introduce solder flux into the joint or surrounding area as

connectors will be attacked and may fail.

All solder joints should be completed and flux residues removed

before final connection to push-in connections, on the flexible hose.

Do not allow contact with oil or cellulose based paints, paint

thinners or strippers, acid based descalents or aggressive cleaning

agents.

Never operate pump with inlet and/or outlet isolating valves in the

closed position. Damage will occur!

3.11

Hose to pump: The hose should be orientated as shown in Fig. 1 and pushed

firmly into the fitting until the pipe stop resistance is felt.

Pull on the hose to check it is secure and correctly fitted.

3.12

Hose to pipework:
1. The hoses are fitted with plastic push-in connectors, which must only be

connected with the following:

a) 22 mm diameter copper pipe to BS EN 1057 - R250 (half hard) - Table 3.

b) 22 mm plastic pipe to BS 7291 part 1 and part 2 (Table 1), or part 3

(Table 1) plus internal support sleeve*.

* The internal bore of the plastic pipe must be supported against collapse

with the pipe manufacturers recommended support sleeve (pipe insert).

c) Appropriate plumbing fittings that are compatible and will provide a water

tight

connection.

Ensure the pipe is free from all score marks and deformities in the area of the

insertion depth (Fig. 8) and cut the pipe square removing all burrs and sharp

edges to prevent damage to the sealing ‘O’-ring.

2. Prior to inserting pipe into fitting mark the insertion depth on the wall of the

pipe with a soft pencil at a distance of 33 mm from the end to be inserted.

Fig. 8

Pencil
mark

Insert depth

33 mm

22 mm Pipe