2 location - single pump – Stuart Turner Techflo Turbo 15TNH User Manual

Page 6

background image

- 6 -

Cont ...

The following method will help to overcome the problem:

A “U” bend or downward loop in the supply pipe to the pump of 350 mm depth

before rising to the pump should ensure the cylinder vents its air up the

expansion pipe, not up the pump feed (Fig. 3 for Singles and Fig. 4 for Twins).

2 LOCATION - SINGLE PUMP

Single Pump System

Fig. 5

Max. static inlet pressure

8

m

Max. inlet head

8

m

Min. inlet head

0.5

m

Negative

head

Least preferred

area

200

mm

min

350

mm

min

Max. outlet head

8

m

Fig. 3 - Single

Fig. 4 - Twin

hot water
services

least preferred

area

200

mm

min

350

mm

Negative head

Max. inlet head

8

m

Min. inlet head

0.5

m

Max. outlet head

8

m