Hot water connection:
2. 29

Hot water cylinder or storage tank: When a hot water cylinder or storage tank

is used, ensure the pipework size from the cold water storage to the hot water

storage is of adequate size and a minimum of 22 mm for all models.

2.30

Hot water supply: The pump must be supplied with a dedicated feed direct from

the hot water cylinder or storage tank. We recommend the use of the Techflow

top flange Part No 27901 or side flange 27900. See Section 9 for terms of

guarantee.
2.31 The supply must be air free and connection to the cylinder can be made by one of

the methods shown in Fig. 7.

2.32

Expansion pipe: When the method of connection is to be made via the

expansion pipe, the cold water storage cistern should be at least 1 metre above

the top of the hot water cylinder.

Fig. 7

(b) Factory installed
G ¾ secondary
tapping with
22 mm pipework to
pump

(a) Site installed
22 mm Techflange
with 22 mm
pipework to pump

(c) Site installed
G 1 Techflange
with 22 mm
pipework to
pump