Re-positioning of Pressure Vessel

The pressure vessel can be rotated to alternative positions (Figs. 4, 5 & 6) in the event of

the factory fitted position being unsuitable for a specific installation.

a) Remove pressure vessel by unscrewing anti-clockwise.

b) Using a 2 mm allen key, carefully loosen all three retaining grub screws by two

turns

(Fig.

3).

c)

Warning - Care must be taken when re-positioning the pressure vessel to

ensure no strain is placed upon the pressure

switch or reed switch cables.

The flow switch assembly can now be carefully

rotated to an alternative position

(Figs. 4, 5 & 6).

d) Ensure all three grub screws are

re-tightened securely to a torque of

2.2 Nm (1.62 lbf feet).

e) Re-fit the pressure vessel

ensuring the ‘O’-ring seal is

in place (see pre-installation

section).

Fig. 3

Grub Screws
(3 off)

Outlet Tower can be swivelled at
this joint line after loosening the
3 equi-spaced grub screws

Motor

Motor

Motor

Factory fitted position
U1.4 bar

Area for alternative fitting positions

Area for alternative fitting positions

Area for alternative fitting positions

Factory fitted position
U3.0 bar, U3.5 bar

Factory fitted position
U4.5 bar

Fig. 4

Fig. 5

Fig. 6