TYPICAL INSTALLATION (Cold Water, Universal Duty, Single Pump System)
The plumbing installation
must comply with the
following:
The Water Supply (Water Fittings)
Regulations 1999.
BS6700 and building regulations.
Be installed by a competent person.
If in doubt contact Stuart Turner Ltd
This diagram should be used for
schematic reference only
1: Isolating valve (not supplied)
2: Inlet strainer
3: Flexible hose
STEP 1: PRE-INSTALLATION ASSEMBLY
Pressure Check and Assembly of Pressure Vessel
a) Certain models are is supplied in two parts, the main pump and the pressure vessel.
The pressure vessel is pre-charged with air at the factory (see table below). This
pressure should be checked at the Schrader valve (Fig. 2) using a tyre pressure
gauge and adjusted if necessary using a car or bicycle pump prior to installation.
b) To assemble the vessel (when applicable), remove protective plastic cap from fitting
point. Ensure that the ‘O’-ring is present and correctly fitted in the location groove at
the bottom of the fitting point. Screw the pressure vessel clockwise into the fitting
point until hand tight to achieve a water tight connection.
NOTE: Do not over tighten pressure vessel.
1
1
1
1
2
3
3
Fig. 1
Fig. 2
Detail view of
‘O’-Ring groove
in fitting point
‘O’-Ring
Schrader valve
(under cap)
Pressure vessel
‘O’-Ring
Fitting point
Model
Air Precharge
bar (psi)
All Models
0.9 (13)