background image

- 16 -

4. Starting

The

Pump

a) Ensure all outlets are closed, turn power supply ‘on’ - pump will start, pressurise

the system then stop.

b) Open and close all outlets in turn associated with the pump, (including w/c

systems) allowing water to flow from each outlet until all air is purged. As each

outlet is opened and closed, the pump will start and stop respectively.

Note: After closing the outlet there will be a small delay time before the pump

stops, which is normal.

Any tap or control valve within the system when opened and closed will now turn

the pump on/off. Providing this is the case the system is now operating correctly.

c) Carefully check pump and pipework for leaks whilst pump running and stationary

before leaving the installation unattended.

For Further Technical Support

Phone the Stuart Turner Pump Assist team on 0844 98 000 97. Our staff are trained to

help and advise you over the phone or arrange for a service engineer to call.

MAINTENANCE

WARNINGS:

Care should be taken to protect pump from frost and freezing,

particularly when located in a loft installation.

Pump Location

If possible site the pump in a location where in the unlikely event of a

water leak, any spillage is contained or routed to avoid electrics or

areas sensitive to water damage.

1. No routine maintenance is required, but provision should be made

for easy access to the pump to allow repairs due to normal wear

and

tear.

2. Disconnect electrical supply before working on pump.
3. Turn off water supplies to the pump and release pressure by opening water outlets

before attempting maintenance.

4. The inlet strainer incorporates a removable gauze filter which may require periodic

cleaning. The frequency of this operation is dependent upon installation conditions.

The strainer is located in the inlet pipework to the pump (see page 11). The gauze

filter is removed as follows:-

a) Isolate pump electrically.

b) Release all system pressure.

c) Isolate water supply.

d) Remove screwed hexagonal plug from strainer body (see page 11).

e) Remove and clean stainless steel gauze filter.

f) Reassemble gauze and secure plug tightly.

g) Turn on water supplies, connect power supply and test.

5. The pressure vessel air pre-charge does not require routine maintenance. Should

ever the need arise for the vessel to have its air pre-charge checked or replenished, it

should be carried out as follows:-

a) Isolate pump electrically.

b) Isolate both the hot and cold inlet water supplies by closing the appropriate

isolating

valves.