Fill new tank, Vcx-1, Page 5 – MAHLE RTI VCX-1 User Manual
Page 6
![background image](/manuals/360664/6/background.png)
Page 5
Valve
Cone Adapter
New Coolant
Tank
Clear Hose
50/50 Mix Water/Coolant
Adapter Hose
Tank
Waste Coolant
(VACUUM)
(PRESSURE)
VCX-1
HOME
FILL NEW TANK
EMPTY RADIATOR
FILL RADIATOR
FILL NEW TANK
EMPTY NEW TANK
TOP OFF
EMPTY NEW TANK
TOP OFF
HOME
HOME
EMPTY RADIATOR
EMPTY WASTE TANK
EMPTY WASTE TANK
WASTE COOLANT
NEW COOLANT
Fill New Tank
1.
Turn all panel valves to the Home position.
2.
Connect shop air to VCX Shop Air Coupler.
3.
Turn all panel valves to the Fill New Tank position as shown in the illustration below. This
orientation can also be obtained by positioning the panel valves toward the green highlights
closest to each valve.
4.
Place the Cone Adapter, with the Adapter Hose attached, into the container of new coolant.
Open the Cone Adapter Valve to draw coolant into the New Coolant Tank.
5.
Raise the hose out of the container of new coolant when the desired fluid level is reached in
the New Coolant Tank.
6.
Close the Cone Adapter Valve.
7.
Turn all valves to the Home position when done.
Note: DO NOT OVERFILL.