Auto Tire Fill System
Operation Instructions
1. Verify “Red” slider valve is in down position
2. Attach air supply (150 PSI max) to NTF unit
3. Plug in the Auto Tire Fill System
4. Turn both valves on NTF unit to “FILL TIRE”
5. Connect hoses to tires
6. Set the final target pressure by pressing + or - buttons
7. To change Over Pressure and Nitrogen Purge Cycles
Settings, see sections below
8. Move “Red” slider valve to up position
9. Press N2 button once for Standard Inflation,
or
hold
N2 button to invoke Nitrogen Purge Cycle
- Standard Inflation will inflate or deflate to the
target pressure
- One complete Nitrogen Purge Cycle is the
process in which the Auto Tire Fill System will
deflate to 3 PSI, Inflate to target pressure, deflate
to 50% of target pressure, then inflate to final target
pressure (If 2 or more Nitrogen Purge Cycles are
programmed, the above process will be repeated)
10. When unit beeps 5 consecutive times, slide “Red”
valve to down position
11. Wait 10 seconds before disconnecting hoses
Over Pressure Setting (OPS)
1. Plug in the Auto Tire Fill System
2. Press
button ONCE
3. Press + or - buttons to change the Over Pressure
Setting
4. Press N2 button to save the Over Pressure Setting
Nitrogen Purge Cycle Setting (N2P)
1. Plug in the Auto Tire Fill System
2. Press
button TWICE
3. Press + or - buttons to change the number of Purge
Cycles
4. Press N2 button to save the number of Purge Cycles
Buzzer Volume Setting
1. Make sure the Auto Tire Fill System is unplugged
2. Press and hold N2 button and - button simultaneously
3. While holding N2 button and - button, plug in the
Automatic Inflation Unit
4. When “Vol” appears on the screen, release the N2
button and - button
5. Adjust the volume using the + and - buttons
6. Press the N2 button to save the volume setting
Inlet Port
Red Slider Valve
Silencer Plug
Error Messages
Error
Possible Cause
Solution
ER1
Unstable pressure
Verify that air chuck is pressed
all the way onto the tire
ER2
Unstable pressure,
incorrect supply pressure,
or Inflate/deflate valve
connections are reversed
Verify that air chuck is pressed
all the way onto the tire. Check
valve connections on PCB.
ER3
Low or no supply pressure
Verify that air chuck is pressed
all the way onto the tire
ER4
Initial or final pressure is
too high, exceeds
maximum pressure by
more than 20 psi, 140
kPa, or 1.4 bar
Turn bottom valve on NTF unit
to vacuum tire. Turn off power
for a minimum of 5 seconds. If
error reappears, call RTI
ER5
Low supply voltage
Check power supply, message
will clear when correct voltage
is restored
ER6
Program or PCB error
Turn off power for a minimum of
5 seconds. If error reappears,
call RTI
ER8
Calibration error
Calibration required, call RTI
ER9
Calibration error
Turn off power for a minimum of
5 seconds. If error reappears,
call RTI
Troubleshooting
Problem
Possible Cause
Solution
No Display
No power supply to
Auto Inflation Unit
Check power
supply
The display will not
move or is stuck on a
particular value
Switch is damaged
Call RTI
The unit deflates very
slowly
The silencer plug on
the valve is blocked
Remove and clean
silencer plug
The Auto Inflation
Unit no longer beeps
The beeper is
damaged
Call RTI
The inflation process
commences but does
not complete
Low supply pressure
Verify that air chuck
is pressed all the
way onto the tire