Yokogawa EJA115 User Manual
Page 2
i
CONTENTS
IM 01C22T01-01E
CONTENTS
ZERO POINT ADJUSTMENT ....................................................................... 1-1
Zero Point Adjustment ........................................................................ 1-1
Using the HART Communicator ................................................... 1-2
Using the Transmitter Zero-adjustment Screw ............................ 1-2
Auto LRV (Change Low Range Value) ............................................... 1-3
Using Model 275 — Apply Values ............................................... 1-3
Setting the Range Using the Range-setting Switch .................... 1-3
HART COMMUNICATOR OPERATION ....................................................... 2-1
Conditions of Communication Line ..................................................... 2-1
Interconnection Between DPharp and HART Communicator ...... 2-1
Communication Line Requirements ............................................. 2-1
Basic Operation of the HART Communicator (Model 275) ................ 2-2
Keys and Functions ...................................................................... 2-2
Calling Up Menu Addresses ........................................................ 2-3
Entering, Setting, and Sending Data ........................................... 2-4
Parameter Usage and Selection .................................................. 2-5
Menu Tree .................................................................................... 2-6
Setting Parameters ....................................................................... 2-7
Tag No. ........................................................................................ 2-7
Range Change ............................................................................ 2-7
Output Mode (Linear/Sq root) ..................................................... 2-8
Damping Time Constants ............................................................ 2-9
Output Signal Low Cut Mode Setup ............................................ 2-9
Bi-directional Flow Measurement .............................................. 2-10
Change Output Limits ............................................................... 2-10
Integral Indicator Display Mode ................................................. 2-10
(10) Integral Indicator Scale ............................................................. 2-10
(11) Unit for Displayed Temperature ................................................. 2-12
(12) Unit for Displayed Static Pressure ............................................ 2-12
(13) Test Output ................................................................................ 2-13
(14) Sensor Trim ............................................................................... 2-13
(15) Trim Analog Output ................................................................... 2-14
(16) Burst Mode ................................................................................ 2-16
(17) Multidrop Mode ......................................................................... 2-17
(18) External Switch Mode ............................................................... 2-17
(19) Software Write Protect .............................................................. 2-18
(20) Hardware Write Protect and Burnout Direction
(with Optional code /F1) ............................................................ 2-19
O Unit Select ......................................................................... 2-19
2.4
Checking for Problems ............................................................... 2-20
Identify Problems with HART Communicator ............................ 2-20
Checking with Integral Indicator ................................................ 2-21
FD No. IM 01C22T01-01E
8th Edition: Oct. 2008(YK)
All Rights Reserved, Copyright © 1995, Yokogawa Electric Corporation